SECTION 7 - DIAGNOSTIC TROUBLE CODES
7-12
3121788
33406 LIFT UP VALVE – SHORT TO
GROUND
None
3_3
• Disable Output
• Lift Up State = PREVENTED
Short to Ground was detected on LIFT_UP_VLV
X
33407 LIFT DOWN VALVE – SHORT TO
GROUND
None
3_3
• Disable Highside Output
• Open Lowside Output
• Lift Down State = PREVENTED
• Lift Up State = PREVENTED
Short to Ground was detected on LIFT_DN_VLV
•
This fault covers both if the Highside Output
or if the Lowside Output is shorted to Ground.
•
If Lowside is shorted to Ground, the feedback
will read 0 mA while the Highside is com-
manding a PWM… this shall lead to this
fault being triggered.
X
335
LIFT DOWN VALVE – SHORT TO
BATTERY
None
3_3
• Disable Highside Output
• Open Lowside Output
• Lift Down State = PREVENTED
• Lift Up State = PREVENTED
Short to Battery was detected on LIFT_DN_VLV
•
This fault covers both if the Highside Output
or if the Lowside Output is shorted to Battery.
X
33537 AUXILIARY LIFT DOWN VALVE -
SHORT TO GROUND
None
3_3
• Disable Highside Output
• Open Lowside Output
• LiftDownState = PREVENTED
• LiftUpState = PREVENTED
Short to Ground was detected on
LIFT_DN_VLV_2 AND {MACHINE SETUP->
MODEL->4047R}
X
33538 AUXILIARY LIFT DOWN VALVE -
OPEN CIRCUIT
None
3_3
• Disable Highside Output
• Open Lowside Output
• LiftDownState = PREVENTED
• LiftUpState = PREVENTED
Open Circuit detected on LIFT_DN_VLV_2 AND
{MACHINE SETUP-> MODEL->4047R}
X
33539 AUXILIARY LIFT DOWN VALVE -
SHORT TO BATTERY
None
3_3
• Disable Highside Output
• Open Lowside Output
• LiftDownState = PREVENTED
• LiftUpState = PREVENTED
Short to Battery was detected on
LIFT_DN_VLV_2 AND {MACHINE SETUP->
MODEL->4047R}
X
33562 BEACON LIGHT – SHORT TO
BATTERY
None
3_3
• Disable output
• No motion restrictions
Short to Battery was detected on BEACON AND
{MACHINE SETUP-> BEACON=YES}.
•
This will only be triggered when ARMGUARD
is active and the short to battery occurs under
the Arm guard limit.
X
336
LIFT DOWN VALVE – OPEN CIR-
CUIT
None
3_3
• Disable Highside Output
• Open Lowside Output
• LiftDownState = PREVENTED
• LiftUpState = PREVENTED
Open Circuit detected on LIFT_DN_VLV
X
3361 BRAKE - SHORT TO GROUND
None
3_3
• BrakeReleaseState = FALSE
(Brake Release Option is not
allowed to disengage brakes)
• Disable output
Short to Ground was detected on the
GM_V5-5_Tow_Out digital output. This DTC
shall only be reported if the BrakeReleaseState
was set to TRUE
X
33674 PLATFORM POWER – SHORT TO
BATTERY
None
3_3
GroundMode
• Disable output
Short to Battery was detected on
PLATFORM_PWR
Ignore this Fault in PlatformMode
X
33675 PLATFORM POWER – OPEN
CIRCUIT
None
3_3
• N/A
Ignore this fault for following reasons.
•
N/A in Ground Mode
•
No diagnostic value in Platform Mode, would
only increase startup time.
X
Table 7-1. Diagnostic Trouble Codes (DTC)
DTC
Help Message
Alarm
Flash
Code
Action
Trigger