The input ratings shown on the dryer data label are for
elevations up to 2,000 feet (610 meters), unless elevation
requirements of over 2,000 feet (610 meters) were specified
at the time the dryer order was placed with the factory. The
adjustment or conversion of dryers in the field for elevations
over 2,000 feet (610 meters) is made by changing each burner
orifice. If this conversion is necessary, contact the reseller
who sold the dryer or contact the factory.
Important
This gas dryer is not provided with an internal gas
supply shutoff and an external gas supply shutoff
must be provided.
Technical Gas Data
Gas Specifications
Shaded areas are stated in metric equivalents
*Measured at outlet side of gas valve pressure tap when gas valve is on.
Gas Connections
Inlet connection ............ 1/2” N.P.T.
Inlet supply size ........... 1/2” Diameter Pipe (minimum)
Heat input (per dryer) .. 95,000 Btu/hr (23,940 kcal/hr)
Natural Gas
Regulation is controlled by the dryer’s gas valve’s internal
regulator. Incoming supply pressure must be consistent
between a minimum of 6.0 inches (14.92 mb) and a maximum
of 12.0 inches (29.9 mb) water column (W.C.) pressure.
Liquid Propane (L.P.) Gas
Dryers made for use with L.P. gas have the gas valve’s internal
pressure regulator blocked open so that the gas pressure
must be regulated upstream of the dryer. The pressure
measured at each gas valve pressure tap must be a
consistent 10.5 inches (26.1 mb) water column. There is no
regulator or regulation provided in an L.P. dryer. The pressure
must be regulated at the source (L.P. tank) or an external
regulator must be added to each dryer.
Shaded area is stated in metric equivalent
* Drill Measurement Size (D.M.S.) equivalents are as follows:
Natural Gas ........................... #29 = 0.1360” (3.4540 mm).
Liquid Propane Gas ............... #46 = 0.0810” (2.0574 mm).
!
Type of Gas
Manifold Pressure*
In-Line Pressure
Natural
3.5 inches W.C.
6.0-12.0 inches W.C.
8.7 mb
14.92 - 29.9 mb
Liquid
Propane
10.5 inches W.C.
11.0 inches W.C.
26.1 mb
27.4 mb
TYPE OF GAS
Btu/hr
Rating
kcal/hr
Rating
Natural
Liquid Propane
Qty.
D.M.S.*
Part No.
Qty.
D.M.S.*
Part No.
95,000
23,940
2
#29
140820
2
#46
140806
LIQUID PROPANE CONVERSION KIT PART NUMBER 883306
!
!
!
!
!
Gas Information______________________
It is your responsibility to have all plumbing connections made
by a qualified professional to ensure that the gas plumbing
installation is adequate and conforms to local and state
regulations or codes. In the absence of such codes, all
plumbing connections, materials, and workmanship must
conform to the applicable requirements of the National Fuel
Gas Code ANSI Z223.1-LATEST EDITION, or in Canada, the
Canadian Installation Codes CAN/CGA-B149.1-M91 (Natural
Gas) or CAN/CGA-B149.2-M91 (Liquid Propane [L.P.] Gas) or
LATEST EDITION.
Important
Failure to comply with codes or ordinances,
and/or requirements in this manual, can result in
personal injury and improper operation of the dryer.
The dryer and its individual shutoff valves must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess
of 1/2 psig (3.5 kPa). The dryer must be isolated from the
gas supply piping system by closing its individual manual
shutoff valve during any pressure test of the gas supply piping
system at test pressures equal to or less than 1/2 psig (3.5
kPa).
Important
Failure to isolate or disconnect the dryer from
supply as noted can cause irreparable damage
to the gas valve, which will
void the warranty.
Warning
Fire or explosion could result due to failure of
isolating or disconnecting the gas supply as
noted.
Gas Supply
The gas dryer installation must meet the American National
Standard...National Fuel Gas Code ANSI Z223.1-LATEST
EDITION, or in Canada, the Canadian Installation Codes CAN/
CGA-B149.1 M91 (Natural Gas) or CAN/CGA-B149.2-M91 (L.P.
Gas) or LATEST EDITION, as well as local codes and
ordinances and must be done by a qualified professional.
Note
Undersized gas piping will result in ignition
problems, slow drying, increased use of energy,
and can create a safety hazard.
The dryer must be connected to the type of heat/gas indicated
on the data label. If this information does not agree with the
type of gas available, do not operate the dryer. Contact the
reseller who sold the dryer or contact the factory.
Important
Any burner changes or conversions must be
made by a qualified professional.