IMPORTANT:
THIS GAS DRYER
IS
NOT
PROVIDED WITH AN INTERNAL GAS SUPPLY
SHUTOFF AND AN EXTERNAL GAS SUPPLY SHUTOFF
MUST BE
PROVIDED.
2. Technical Gas Data
a. Gas Specifications
TYPE OF GAS
NATURAL
LIQUID PROPANE
Manifold Pressure*
3.5 inches W.C.
8.7 mb
10.5 inches W.C.
26.1 mb
In-Line Pressure
6.0 - 12.0 inches W.C.
14.92 - 29.9 mb
11.0 inches W.C.
27.4 mb
TYPE OF GAS
Liquid
Propane
Conversion Kit
Part Number
Btu/hr
Rating
kcal/hr
Rating
Natural
Liquid Propane
Qty.
D.M.S.*
Part No. Qty.
D.M.S.*
Part No.
95,000
23,940
2
#30
140819
2
#48
140804
883361
Shaded area is stated in metric equivalent
* Drill Measurement Size (D.M.S.) equivalents are as follows:
Natural Gas ................................ #30 = 0.1285” (3.2639 mm).
Liquid Propane Gas ................... #48 = 0.0760” (1.9304 mm).
Shaded areas are stated in metric equivalents
* Measured at outlet side of gas valve pressure tap when gas valve is on.
b. Gas Connections
Inlet connection ___________ 1/2” N.P.T.
Inlet supply size ___________ 1/2” Diameter Pipe (minimum)
Btu/hr input (per dryer) _____ 95,000 (23,940 kcal/hr)
1) Natural Gas
Regulation is controlled by the dryer’s gas valve’s internal regulator. Incoming supply pressure
must
be
consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches (29.9 mb)
water column (W.C.) pressure.
2) Liquid Propane (L.P.) Gas
Dryers made for use with L.P. gas have the gas valve’s internal pressure regulator blocked open so that
the gas pressure
must be
regulated upstream of the dryer. The pressure measured at each gas valve
pressure tap
must be
a consistent 10.5 inches (26.1 mb) water column. There is no regulator or
regulation provided in an L.P. dryer. The water column pressure
must be
regulated at the source (L.P.
tank) or an external regulator
must be
added to each dryer.