 |  JL Audio - XD400/4v2 Owner’s Manual  

TURN-ON OPTIONS

The XD400/4v2 can be switched on and off 

using one of three methods, determined by the 
position of the amplifier’s “Turn-On Mode” 
switch. Please read these options and decide 
which is best suited for your specific system.

1) +12V remote turn-on lead 

2) Signal-sensing turn-on circuit.

3) DC offset-sensing turn-on circuit
 

+12 V Remote Turn-On: This is the preferred 
method for turning the amplifier on/off. The 
amplifier will turn on when +12 V is present at 
its “Remote” input and turn off when +12 V is 
switched off. This +12 V remote turn-on signal 
is typically controlled by a source unit’s remote 
turn-on wire. The XD400/4v2’s “Remote” turn-on 
connector will accept 18 AWG – 12 AWG wire. To 
connect the remote turn-on wire to the amplifier, 
first back out the set screw on the top of the 
terminal block, using the supplied 2.5 mm hex 
wrench. Strip 1/2 inch (12mm) of wire and insert 
the bare wire into the terminal block, seating it 
firmly so that no bare wire is exposed. While 
holding the wire in the terminal, tighten the set 
screw firmly, taking care not to strip the head of 
the screw and making sure that the wire is firmly 
gripped by the set screw.

If a source unit does not have a dedicated 

remote turn-on output, consider one of the 

following alternative turn-on options:

These methods are useful when a conventional 

+12 V remote turn-on signal is not available in a 
system. These allow you to operate the amplifier 
without having to locate a remote turn-on lead at 
the source unit, which can be very useful when 
interfacing the amplifier with OEM (factory) 

audio systems that do not use conven12 V 
turn-on leads.

Depending on the characteristics of the audio 

signal, one of the following methods may work 
better than the other. We recommend trying DC 
Offset-Sensing first as it does not require a long 
delay to turn the system off after the signal is 
shut off.

DC Offset-Sensing: The amplifier will turn on 

and off by detecting the presence of a very small 
DC signal (offset) that is typical in the audio 
output of most OEM (factory) source units and 
amplifiers. The amplifier will turn on and off in 
reaction to the presence or absence of this DC 
Offset. The sensitivity of this circuit is designed 
for high-level (speaker level) signals, not for low-
level (preamp level) signals. The circuit senses 

the left-channel signal only.

Signal-Sensing: The amplifier will turn on 

and off by detecting the presence of a full-range 
audio signal at its left-channel input. After 
approximately 30 seconds, the amplifier will shut 
off. The sensitivity of this circuit is designed for 
high-level (speaker level) signals, not for low-level 
(preamp level) signals. The circuit is tuned to 
react to signals at mid-range frequencies. This 
prevents false switching from signals created by 
moving loudspeakers that are in parallel with the 
amplifier’s input signal.

In signal sensing and DC offset sensing 

applications, the amplifier’s “Remote” turn-on 
terminal becomes a remote turn-on output. 
This allows the XD400/4v2 to turn on other 
amplifiers in the audio system that do not have 
signal sensing or DC offset sensing. Of course 
the XD400/4v2 must be the first amplifier in the 
signal path for this to function properly.

INPUT SECTION

The XD400/4v2’s input section allows you to 

send signals to the amplifier section through the 
use of two or four differential-balanced inputs.

Input connections are via up to two pairs of 

traditional RCA-type jacks.

 

Содержание XD 400/4v2

Страница 1: ...allation equipment to ensure optimum performance from this product Should you decide to install the amplifier yourself please take the time to read this manual thoroughly to familiarize yourself with...

Страница 2: ...space provided below The serial number can be found on the bottom panel of the amplifier and on the amplifier packaging Serial Number INSTALLATION APPLICATIONS This amplifier is designed for operatio...

Страница 3: ...ventilated environment and in a manner which does not interfere with your vehicle s safety equipment air bags seat belt systems ABS brake systems etc You should also take the time to securely mount th...

Страница 4: ...eaker systems to the amplifier mounting location 6 Find a good solid metal grounding point close to the amplifier and connect the negative power wire to it using appropriate hardware use of the JL Aud...

Страница 5: ...the set screw firmly taking care not to strip the head of the screw The ground connection should be made using 8 or 4 AWG wire and should be kept as short as possible while accessing a solid piece of...

Страница 6: ...ventional 12 V turn on leads Depending on the characteristics of the audio signal one of the following methods may work better than the other We recommend trying DC Offset Sensing first as it does not...

Страница 7: ...ts an input sensitivity range between 800mV and 8V This is useful for certain high output preamp level signals as well as speaker level output from source units and small amplifiers To use speaker lev...

Страница 8: ...audio system Input Mode 2 Ch 4 Ch All 3 4 1 2 Sum Preouts From Remote Level Mode nal Input Voltage Low High e 1 Filter Mode Controls The XD400 4v2 employs 12dB per octave filters for each pair of cha...

Страница 9: ...y added to the system This pass through preamp output can be configured two different ways using the switch labeled Preouts From 1 1 2 the preamp output delivers the same signal that is connected to t...

Страница 10: ...put of two amplifier channels to drive a single load When bridged each channel produces signals of equal magnitude but opposite polarity The combined output of the two channels provides twice the outp...

Страница 11: ...ticking or thumping noise in the output Over current conditions can be caused by a speaker impedance lower than the optimum load impedance range for the amplifier or a short circuit in the speaker wi...

Страница 12: ...D400 4v2 s Input Sens settings and will not be user adjustable from the front of the vehicle B Fade Subwoofer Level vs HF Level Req uired a source unit or processor with two pairs of stereo outputs In...

Страница 13: ...pair of source unit outputs is connected to the subwoofer amplifier inputs Res ult with this option the user has the ability to fade the level of the subwoofer amplifier s input relative to the HF ch...

Страница 14: ...input sensitivity adjustment according to the nominal impedance of the speaker system connected to the amplifier outputs 6 Verify that you have disconnected the speakers before proceeding Play a track...

Страница 15: ...tio 104 dB referred to rated power A weighted 20 Hz 20 kHz noise bandwidth 84 dB referred to 1W A weighted 20 Hz 20 kHz noise bandwidth Frequency Response 12 Hz 22 kHz 0 1dB Damping Factor 150 4 ohms...

Страница 16: ...ay is required To test for this problem jump the 12VDC wire to the Remote terminal to see if the amplifier turns on I get a repetitive ticking or popping sound coming out of the speaker s Check the sp...

Страница 17: ...while an appropriate test tone is played through the source unit disconnect the input cables from the amplifier prior to this test The frequency used should be in the range that is to be amplified by...

Страница 18: ...JL Audio XD400 4v2 Owner s Manual INSTALLATION NOTES Use this diagram to document your amplifier s switch and control positions 4 Channel Amplifier Rem Offset Signal Input Voltage Low High Turn On Mo...

Страница 19: ...19...

Страница 20: ...etail and no warranties whether express or implied shall apply to this product thereafter Some states do not allow limitations on implied warranties therefore these exclusions may not apply to you Thi...

Отзывы: