TURN-ON OPTIONS

The XD200/2v2 can be switched on and off 

using one of three methods, determined by the 
position of the amplifier’s “Turn-On Mode” 
switch. Please read these options and decide 
which is best suited for your specific system.

1) +12V remote turn-on lead 

2) Signal-sensing turn-on circuit.

3) DC offset-sensing turn-on circuit

+12 V Remote Turn-On: This is the preferred 

method for turning the amplifier on/off. The 
amplifier will turn on when +12 V is present at 
its “Remote” input and turn off when +12 V is 
switched off. This +12 V remote turn-on signal 
is typically controlled by a source unit’s remote 
turn-on wire. The XD200/2v2’s “Remote” turn-
on connector will accept 18 AWG – 12 AWG 
wire. To connect the remote turn-on wire to 
the amplifier, first back out the set screw on the 
top of the terminal block, using the supplied 2.5 
mm hex wrench. Strip 1/2 inch (12mm) of wire 
and insert the bare wire into the terminal block, 
seating it firmly so that no bare wire is exposed. 
While holding the wire in the terminal, tighten 
the set screw firmly, taking care not to strip the 
head of the screw and making sure that the wire 
is firmly gripped by the set screw.

If a source unit does not have a dedicated 

remote turn-on output, consider one of the 

following alternative turn-on options:

These methods are useful when a conventional 

+12 V remote turn-on signal is not available in a 
system. These allow you to operate the amplifier 
without having to locate a remote turn-on lead at 

the source unit, which can be very useful when 
interfacing the amplifier with OEM (factory) 
audio systems that do not use conven12 V 
turn-on leads.

Depending on the characteristics of the audio 

signal, one of the following methods may work 
better than the other. We recommend trying DC 
Offset-Sensing first as it does not require a long 
delay to turn the system off after the signal is 
shut off.

DC Offset-Sensing: The amplifier will turn on 

and off by detecting the presence of a very small 
DC signal (offset) that is typical in the audio 
output of most OEM (factory) source units and 
amplifiers. The amplifier will turn on and off in 
reaction to the presence or absence of this DC 
Offset. The sensitivity of this circuit is designed 
for high-level (speaker level) signals, not for low-
level (preamp level) signals. The circuit senses 

the left-channel signal only.

Signal-Sensing: The amplifier will turn on 

and off by detecting the presence of a full-range 
audio signal at its left-channel input. After 
approximately 30 seconds, the amplifier will shut 
off. The sensitivity of this circuit is designed for 
high-level (speaker level) signals, not for low-level 
(preamp level) signals. The circuit is tuned to 
react to signals at mid-range frequencies. This 
prevents false switching from signals created by 
moving loudspeakers that are in parallel with the 
amplifier’s input signal.

In signal sensing and DC offset sensing 

applications, the amplifier’s “Remote” turn-on 
terminal becomes a remote turn-on output. 
This allows the XD200/2v2 to turn on other 
amplifiers in the audio system that do not have 
signal sensing or DC offset sensing. Of course, 
the XD200/2v2 must be the first amplifier in the 
signal path for this to function properly.

Содержание NexD XD200/2v2

Страница 1: ...llation equipment to ensure optimum performance from this product Should you decide to install the amplifier yourself please take the time to read this manual thoroughly so as to familiarize yourself...

Страница 2: ...your amplifier requires service or is ever stolen you will need to have a record of the product s serial number Please take the time to enter that number in the space provided below The serial number...

Страница 3: ...eeds to be installed in a dry well ventilated environment and in a manner which does not interfere with your vehicle s safety equipment air bags seat belt systems ABS brake systems etc You should also...

Страница 4: ...systems to the amplifier mounting location 6 Find a good solid metal grounding point close to the amplifier and connect the negative power wire to it using appropriate hardware use of the JL Audio EC...

Страница 5: ...hten the set screw firmly taking care not to strip the head of the screw The ground connection should be made using 8 or 4 AWG wire and should be kept as short as possible while accessing a solid piec...

Страница 6: ...ce unit which can be very useful when interfacing the amplifier with OEM factory audio systems that do not use conventional 12 V turn on leads Depending on the characteristics of the audio signal one...

Страница 7: ...ltage window If you are using an aftermarket source unit with conventional preamp level outputs this is the position you should select The High position on the Input Voltage switch selects an input se...

Страница 8: ...section of a speaker system The division of frequency ranges to different speakers can be done with passive filters coils and or capacitors between the amplifier outputs and the speakers which are ac...

Страница 9: ...er Freq Hz setting After properly adjusting the Input Sens as outlined in Appendix A page 12 you can fine tune the Filter Freq Hz control to achieve the desired system frequency response REMOTE LEVEL...

Страница 10: ...idged configuration Speaker loads below 2 ohms nominal per channel or 4 ohms bridged are not recommended and may cause the amplifier to initiate a protection mode which reduces power output BRIDGING C...

Страница 11: ...ver current conditions can be caused by a speaker impedance lower than the optimum load impedance range for the amplifier or a short circuit in the speaker wiring The latter can result from a short ci...

Страница 12: ...for input sensitivity adjustment according to the nominal impedance of the speaker system connected to the amplifier outputs 6 Verify that you have disconnected the speakers before proceeding Play a t...

Страница 13: ...4 dB referred to rated power A weighted 20 Hz 20 kHz noise bandwidth 84 dB referred to 1W A weighted 20 Hz 20 kHz noise bandwidth Frequency Response 12 Hz 22 kHz 0 1dB Damping Factor 150 4 ohms per ch...

Страница 14: ...st for this problem jump the 12VDC wire to the Remote terminal to see if the amplifier turns on I get a repetitive ticking or popping sound coming out of the speaker s Check the speaker wires for a po...

Страница 15: ...nit while an appropriate test tone is played through the source unit disconnect the input cables from the amplifier prior to this test The frequency used should be in the range that is to be amplified...

Страница 16: ...etail and no warranties whether express or implied shall apply to this product thereafter Some states do not allow limitations on implied warranties therefore these exclusions may not apply to you Thi...

Отзывы: