9
REMOTE LEVEL CONTROL (OPTIONAL)
Remote
Level
Control
CH. 5
(L)
CH. 6
(R)
CH. 3
(L)
CH. 4
(R)
CH. 1
(L)
CH. 2
(R)
Bridged
CH. 7
(L)
CH. 8
(R)
Bridged
Bridged
Bridged
INPUT SECTION
(L)
(R)
CH. 1&2
CH. 3&4
CH. 5&6
CH. 7&8
+24 VDC
Ground
Remote
NOT FOR USE IN 12V SYSTEMS!
With the addition of the optional Remote
Level Control (HD-RLC or MHD-RLC), you
can control the volume of two, four or all eight
channels of the M800/8-24V from the front of
the vessel. This feature can be used for subwoofer
level control, rear channel level control, zone
control, or even as a master volume control for
the system.
The HD-RLC connects to the jack labeled
“Remote Level Control” on the Connection Panel
of the amplifier using a standard telephone cable
(supplied with the HD-RLC). If desired, multiple
M (and MHD) amplifiers can be controlled from
a single HD-RLC controller using a simple,
non-duplex phone line “splitter” and multiple
phone cables.
When connected to the amplifier, the
HD-RLC operates as follows. At full counter-
clockwise rotation, the audio will mute
completely. At full clockwise rotation the level
will be the same as if the HD-RLC was not
connected at all. In other words, it operates
strictly as a level attenuator.
Remote
Level
Mode
All | 5- 8 | 7&8
Input Mode
2 Ch. | 4 Ch. | 8 Ch.
CH. 7
(L)
CH. 8
(R)
CH. 7 & 8
Filter Mode
Filter Freq. (Hz)
Input
Sens.
Off | HP | LP
CH. 5
(L)
CH. 6
(R)
CH. 3
(L)
CH. 4
(R)
CH. 1
(L)
CH. 1 & 2
CH. 3 & 4
CH. 5 & 6
CH. 2
(R)
Filter Mode
Filter Freq. (Hz)
Input
Sens.
Off | HP | LP
Filter Mode
Filter Freq. (Hz)
Input
Sens.
Off | HP | LP
Filter Mode
Filter Freq. (Hz)
Input
Sens.
Off | HP | LP
CH. 1
CH. 2
CH. 3
CH. 4
CH. 5
CH. 6
(L)
(R)
CH. 7
CH. 8
INPUT SEC
TION
+24 VDC
Ground
Remote
2 Ch. Input 1 feeds CH. 1, CH. 3, CH. 5 & CH. 7
Input 2 feeds CH. 2, CH. 4, CH. 6 & CH. 8
4 Ch. Input 1 feeds CH. 1 & CH. 3
Input 2 feeds CH. 2 & CH. 4
Input 5 feeds CH. 5 & CH. 7
Input 6 feeds CH. 6 & CH. 8
8 Ch. Each input feeds its
corresponding output channel
INPUT MODES:
Marine 8 Channel Amplifier
NOT FOR USE IN 12V SYSTEMS!
-24V
“Remote Level Mode” Switch: This switch
allows you to assign the operation of the
HD-RLC to one, two or all four pairs of channels.
In the “All” position, the HD-RLC knob will
affect all four channel pairs equally.
In the “5-8” (middle) position, only the level
of channels 5, 6, 7 and 8 will be affected by the
HD-RLC knob (channels 1, 2, 3 and 4 will not).
In the “7 & 8” position, only the level of
channels 7 and 8 will be affected by the HD-RLC
knob (channels 1 through 6 will not).
Содержание M800/8-24V
Страница 13: ...13...