background image

9

REMOTE LEVEL CONTROL (OPTIONAL)

Remote

Level

Control

CH. 5

(L)

CH. 6

(R)

CH. 3

(L)

CH. 4

(R)

CH. 1

(L)

CH. 2

(R)

Bridged

CH. 7

(L)

CH. 8

(R)

Bridged

Bridged

Bridged

INPUT SECTION

(L)

(R)

CH. 1&2

CH. 3&4

CH. 5&6

CH. 7&8

+24 VDC

Ground

Remote

NOT FOR USE IN 12V SYSTEMS!

With the addition of the optional Remote 

Level Control (HD-RLC or MHD-RLC), you 

can control the volume of two, four or all eight 

channels of the M800/8-24V from the front of 

the vessel. This feature can be used for subwoofer 

level control, rear channel level control, zone 

control, or even as a master volume control for 

the system.

The HD-RLC connects to the jack labeled 

“Remote Level Control” on the Connection Panel 

of the amplifier using a standard telephone cable 

(supplied with the HD-RLC). If desired, multiple 

M (and MHD) amplifiers can be controlled from 

a single HD-RLC controller using a simple,  

non-duplex phone line “splitter” and multiple 

phone cables.

When connected to the amplifier, the 

HD-RLC operates as follows. At full counter-

clockwise rotation, the audio will mute 

completely. At full clockwise rotation the level 

will be the same as if the HD-RLC was not 

connected at all. In other words, it operates 

strictly as a level attenuator.

Remote

Level

Mode

All | 5- 8 | 7&8

Input Mode

2 Ch. | 4 Ch. | 8 Ch.

CH. 7

(L)

CH. 8

(R)

CH. 7 & 8

Filter Mode

Filter Freq. (Hz)

Input 

Sens.

Off | HP | LP

CH. 5

(L)

CH. 6

(R)

CH. 3

(L)

CH. 4

(R)

CH. 1

(L)

CH. 1 & 2

CH. 3 & 4

CH. 5 & 6

CH. 2

(R)

Filter Mode

Filter Freq. (Hz)

Input 

Sens.

Off | HP | LP

Filter Mode

Filter Freq. (Hz)

Input 

Sens.

Off | HP | LP

Filter Mode

Filter Freq. (Hz)

Input 

Sens.

Off | HP | LP

CH. 1

CH. 2

CH. 3

CH. 4

CH. 5

CH. 6

(L)

(R)

CH. 7

CH. 8

INPUT SEC

TION

+24 VDC

Ground

Remote

2 Ch. Input 1 feeds CH. 1, CH. 3, CH. 5 & CH. 7

 

Input 2 feeds CH. 2, CH. 4, CH. 6 & CH. 8

4 Ch. Input 1 feeds CH. 1 & CH. 3 

 

Input 2 feeds CH. 2 & CH. 4 

 

Input 5 feeds CH. 5 & CH. 7 

 

Input 6 feeds CH. 6 & CH. 8

8 Ch.  Each input feeds its 

 

corresponding output channel

INPUT MODES:

Marine 8 Channel Amplifier

NOT FOR USE IN 12V SYSTEMS!

-24V

“Remote Level Mode” Switch:  This switch 

allows you to assign the operation of the 

HD-RLC to one, two or all four pairs of channels.

In the “All” position, the HD-RLC knob will 

affect all four channel pairs equally. 

In the “5-8” (middle) position, only the level 

of channels 5, 6, 7 and 8 will be affected by the 

HD-RLC knob (channels 1, 2, 3 and 4 will not).

In the “7 & 8” position, only the level of 

channels 7 and 8 will be affected by the HD-RLC 

knob (channels 1 through 6 will not).

 

Содержание M800/8-24V

Страница 1: ...the training expertise and installation equipment to ensure optimum performance from this product Should you decide to install the amplifier yourself please take the time to read this manual thoroughl...

Страница 2: ...nty This product is not certified or approved for use in aircraft Do not attempt to bridge the outputs of this amplifier with the outputs of a second amplifier including an identical one PLANNING YOUR...

Страница 3: ...e 2 Ch 4 Ch 8 Ch CH 7 L CH 8 R CH 7 8 Filter Mode Filter Freq Hz Input Sens Off HP LP CH 5 L CH 6 R CH 3 L CH 4 R CH 1 L CH 1 2 CH 3 4 CH 5 6 CH 2 R Filter Mode Filter Freq Hz Input Sens Off HP LP Fil...

Страница 4: ...ve power wire to the negative battery post Use the same size power wire as the wire connected to the 24V connection minimum 4 AWG 5 Run signal cables and remote turn on wire from the source unit to th...

Страница 5: ...ied 2 5 mm hex wrench Strip 1 2 inch 12 mm of insulation from the end of each wire and insert the bare wire into the terminal block seating it firmly so that no bare wire is exposed While holding the...

Страница 6: ...ircuit Remote Level Control C CH 1 L CH 2 R Bridged INPUT SECTION L R CH 1 2 CH 3 4 CH 5 6 CH 7 8 24 VDC Ground Remote NOT FOR USE IN 12V SYSTEMS The M800 8 24V s Remote turn on connector is designed...

Страница 7: ...election pg 8 Ch 1 2 Input Sensitivity Control pg 7 Ch 3 4 Filter Frequency Selector pg 8 Ch 3 4 Filter Mode Selection pg 8 Ch 3 4 Input Sensitivity Control pg 7 Ch 5 6 Filter Frequency Selector pg 8...

Страница 8: ...P Filter Mode Filter Freq Hz Input Sens Off HP LP Filter Mode Filter Freq Hz Input Sens Off HP LP L R 1 Filter Mode Control The M800 8 24V employs a 12dB per octave filter for each pair of channels Ea...

Страница 9: ...audio will mute completely At full clockwise rotation the level will be the same as if the HD RLC was not connected at all In other words it operates strictly as a level attenuator Remote Level Mode A...

Страница 10: ...t and Right speaker connectors only The Left and Right remain unused When bridged each channel pair will deliver optimum power into a single 4 ohm load When a pair of channels are bridged they will de...

Страница 11: ...d and is accompanied by a muting of the affected channel s Because the muting behavior may be very short in duration it may manifest itself as an audible repetitive ticking noise in the output Over cu...

Страница 12: ...ry in the JL Audio amplifiers requires specifically trained service personnel Do not attempt to service the amplifier yourself or through unauthorized repair facilities This will not only void the war...

Страница 13: ...13...

Страница 14: ...nce of the speaker system connected to the amplifier outputs 6 Verify that you have disconnected the speakers before proceeding Play a track with an appropriate sine wave within the frequency range to...

Страница 15: ...referred to rated power A weighted 20 Hz 20 kHz noise bandwidth 84 dB referred to 1W A weighted 20 Hz 20 kHz noise bandwidth Frequency Response 12 Hz 22 kHz 0 1dB Damping Factor 150 4 ohms per ch 50...

Страница 16: ...ired To test for this problem jump the 24VDC wire to the Remote terminal to see if the amplifier turns on I hear a repetitive ticking or popping sound coming out of the speaker s Check the speaker wir...

Страница 17: ...source unit while an appropriate test tone is played through the source unit disconnect the input cables from the amplifier prior to this test The frequency used should be in the range that is to be...

Страница 18: ...ter Mode Inpu Sen Off HP LP CH 1 CH 2 CH 3 CH 4 CH 5 CH 6 L R CH 7 CH 8 INPUT SECTION 24 VDC Ground Remote 2 Ch Input 1 feeds CH 1 CH 3 CH 5 CH 7 Input 2 feeds CH 2 CH 4 CH 6 CH 8 4 Ch Input 1 feeds C...

Страница 19: ...8 Filter Mode Filter Freq Hz Input Sens Off HP LP CH 5 L CH 6 R CH 3 L CH 4 R CH 1 L CH 1 2 CH 3 4 CH 5 6 CH 2 R Filter Mode Filter Freq Hz Input Sens Off HP LP Filter Mode Filter Freq Hz Input Sens...

Страница 20: ...hereafter Some states do not allow limitations on implied warranties therefore these exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights wh...

Отзывы: