PRODUCT DESCRIPTION

The JL Audio M500/3 is a three-channel,  

system amplifier utilizing JL Audio NexD™ ultra-
high speed switching technology for its two main 
channels and NexD™ high-speed switching for 
its subwoofer channel. The NexD™ technologies 
deliver outstanding fidelity and efficiency.

The M500/3 can be operated with a wide 

variety of source units and system configurations.

TYPICAL INSTALLATION SEQUENCE

The following represents the sequence 

for a typical amplifier installation, using 
an aftermarket source unit. Additional 
steps and different procedures may be 
required in some applications. If you 
have any questions, please contact your 
authorized JL Audio dealer for assistance.

  1)  Disconnect the negative battery post 

connection and secure the disconnected cable 
to prevent accidental re-connection during 
installation. This step is not optional.

  2)  Run 4 AWG power wire from the battery 

location to the amplifier mounting location. 
Take care to route the wire in such a way that 
it will not be damaged and will not interfere 
with vessel operation. Use 2 AWG or larger 
power wire and a power distribution block if 
additional amplifiers are being installed with 
the M500/3.

 3)  Connect power wire to the positive battery 

post. Fuse the wire with an appropriate fuse 
block (and connectors) within 18 inches (45 
cm) wire length of the positive battery post. 

This fuse is essential to protect the vessel. Do 

not install the fuse until the power wire has 

been securely connected to the amplifier. 

  4)  Connect negative power wire to the negative 

battery post. Use the same size power 
wire as the wire connected to the “+12V” 
connection (minimum 4 AWG).

  5)  Run signal cables and remote turn-on wire 

from the source unit to the amplifier  
mounting location. 

  6)  Run speaker cables from the speaker systems 

to the amplifier mounting location.

  7)  Securely mount the amplifier.

  8)  Connect the positive and negative power  

wires to the amplifier. A fuse near the 
amplifier is not necessary if the M500/3 is the 
only device being run from the fused main 
power wire. If the fused main power wire is 
shared by the M500/3 and other amplifiers 
or devices, fuse each amplifier/device 
within 12 inches (30 cm) of wire length, 
via a fused distribution block or multiple 
individual fuse blocks/on-board fuses.  

 9)  Connect the remote turn-on wire  

to the amplifier.

10) Connect the input cables to the amplifier.

11) Connect the speaker cables to the amplifier.

12)  Carefully review the amplifier’s control  

settings to make sure that they are set 
according to the needs of the system.

13)  Install the power wire fuse(s) (50A for a  

single M500/3) and reconnect the negative  
battery post terminal. 

14)  Turn on the source unit at a low level  

to double-check that the amplifier is 
configured correctly. Resist the temptation  
to crank it up until you have verified the  
control settings.

15)  Make necessary adjustments to the input 

sensitivity controls to obtain the right  
overall output and the desired balance  
in the system. See Appendix A (page 14)  
for the recommended input sensitivity  
setting method.

16)  Enjoy the fruits of your labor with your 

favorite music.

Содержание M500/3

Страница 1: ...n equipment to ensure optimum performance from this product Should you decide to install the amplifier yourself please take the time to read this manual thoroughly so as to familiarize yourself with i...

Страница 2: ...to have a record of the product s serial number Please take the time to enter that number in the space provided below The serial number can be found on the bottom panel of the amplifier and on the amp...

Страница 3: ...g the supplied screws so that it does not come loose in the event of a collision or a sudden jolt to the vessel Stupid Mistakes to Avoid Check before drilling any holes in your vessel to make sure tha...

Страница 4: ...power wire has been securely connected to the amplifier 4 Connect negative power wire to the negative battery post Use the same size power wire as the wire connected to the 12V connection minimum 4 A...

Страница 5: ...p 1 2 inch 12 mm of insulation from the end of each wire and insert the bare wire into the terminal block seating it firmly so that no bare wire is exposed While holding the wire in place tighten the...

Страница 6: ...t to strip the head of the screw and making sure that the wire not the insulation is firmly gripped by the wire clamp in the terminal INPUT SECTION L R Remote Level Control CH 1 2 SUB CH Preouts 12 VD...

Страница 7: ...h channel section can be used to match the source unit s output voltage to the input stage of each group of amplifier channels for maximum clean output Rotating the control clockwise will result in hi...

Страница 8: ...switch in each Channel Section Channel 1 2 Filter 2dB octave High Pass only Off Defeats the filter completely allowing the full range of frequencies present at the inputs to feed these channels This i...

Страница 9: ...at all In other words it operates strictly as a level attenuator Remote Level Mode Switch This switch allows you to assign the operation of the HD RLC to the entire amplifier or only the subwoofer ch...

Страница 10: ...combining the output of two amplifier channels to drive a single load When bridged each channel produces signals of equal magnitude but opposite polarity The combined output of the two channels provid...

Страница 11: ...h reduces power output The M500 3 s subwoofer outputs are designed to accept 16 AWG 8 AWG wire To connect the subwoofer wires to the amplifier first back out the set screws on the top of the terminal...

Страница 12: ...tput Over current conditions can be caused by a speaker impedance lower than the optimum load impedance range for the amplifier or a short circuit in the speaker wiring The latter can result from a sh...

Страница 13: ...amplifiers requires specifically trained service personnel Do not attempt to service the amplifier yourself or through unauthorized repair facilities This will not only void the warranty but may resu...

Страница 14: ...cted the speakers before proceeding Play a track with an appropriate sine wave within the frequency range to be amplified by the channel you are adjusting at 3 4 source unit volume 7 Connect the AC vo...

Страница 15: ...s S N Ratio A weighted 20 Hz 20 kHz noise bandwidth Main Channels 104 dB referred to rated power 84 dB referred to 1W Subwoofer Channel 103dB referred to rated power 83dB referred to 1W Frequency Resp...

Страница 16: ...r this problem jump the 12VDC wire to the Remote terminal to see if the amplifier turns on I get a repetitive ticking or popping sound coming out of the speaker s Check the speaker wires for a possibl...

Страница 17: ...it while an appropriate test tone is played through the source unit disconnect the input cables from the amplifier prior to this test The frequency used should be in the range that is to be amplified...

Страница 18: ...18 JL Audio M500 3 Owner s Manual INSTALLATION NOTES Use this diagram to document your amplifier s switch and control positions...

Страница 19: ...19...

Страница 20: ...retail and no warranties whether express or implied shall apply to this product thereafter Some states do not allow limitations on implied warranties therefore these exclusions may not apply to you T...

Отзывы: