C.
After programs setting, press
CLOCK
key then return to present time( CLOCK MODE).
D. TO RESET TIMER
Press
RESET
key, the previous setting time and programs will be cleared to initial state.
E. TO SELECT ON/AUTO/OFF MODE
1. Press MANUAL key to select ON. AUTO, or OFF MODE
2."ON" mode set output at ON state
3."OFF" mode set output at OFF state
4."AUTO" mode set output to program mode. Relay contact will turn ON/OFF according
to the program setting time.
5.After program setting is confirmed, it is necessary to press
MANUAL
key and change
the mode to ensure the Timer working in correct program. Please check the present time.
If it is in the duration of program ON setting time, then press
MANUAL
to make it from
ON to AUTO mode. In case of the present time is now within program OFF setting time,
then make it from OFF to AUTO mode. Because from ON to AUTO, relay contact will be
turned to ON state until next OFF setting time coming. Contrary, from OFF to AUTO,
relay contact will be switched to OFF state and lasting until next ON setting time is
coming.
F. WIRE CONNECTION
Max, Load: 2000VA
Applied Voltage Range: 100-250VAC
Inside Battery: NI-CAD*1 PC(Just for clock operation, not for output ON/OFF switching.)
29
DIMENSIONS