background image

 

C.

 After programs setting, press 

CLOCK

 key then return to present time( CLOCK MODE). 

D. TO RESET TIMER

 

Press 

RESET

 key, the previous setting time and programs will be cleared to initial state. 

E. TO SELECT ON/AUTO/OFF MODE

 

1. Press MANUAL key to select ON. AUTO, or OFF MODE 

2."ON" mode set output at ON state 

 

3."OFF" mode set output at OFF state 

4."AUTO" mode set output to program mode. Relay contact will turn ON/OFF according 

to the program setting time. 

5.After program setting is confirmed, it is necessary to press 

MANUAL

 key and change 

the mode to ensure the Timer working in correct program. Please check the present time. 

If it is in the duration of program ON setting time, then press 

MANUAL

 to make it from 

ON to AUTO mode. In case of the present time is now within program OFF setting time, 

then make it from OFF to AUTO mode. Because from ON to AUTO, relay contact will be 

turned to ON state until next OFF setting time coming. Contrary, from OFF to AUTO, 

relay contact will be switched to OFF state and lasting until next ON setting time is 

coming. 

F. WIRE CONNECTION

 

Max, Load: 2000VA 

Applied Voltage Range: 100-250VAC 

Inside Battery: NI-CAD*1 PC(Just for clock operation, not for output ON/OFF switching.) 

29 

     

 

 

DIMENSIONS 

   

Отзывы: