background image

 
 

Mifare & ISO14443A&ISO14443B&ISO7816                                                   

http://www.jinmuyu.com

 

Copyright © 2003-2014 Jinmuyu Electronics Co., LTD. All rights reserved. 

 

7/19 

 

 

5.2

 

Software connects to the device 

Open the configuration tool. Then click the “Connect” button. Successfully connect as following: 

 

The dialog box will prompt the supported card types. 

 

Note: MR761 and JMY609 have the same "Configuration Software". 

 

 

 

 

 

 

 

 

 

 

 

Содержание JMY609C

Страница 1: ... CONTACTLESS IC CARD READER MODULE JMY609C IC Card Reader User s manual Revision 3 50 Jinmuyu Electronics Co LTD 2012 3 2 Please read this manual carefully before using If any problem please mail to Jinmuyu vip sina com ...

Страница 2: ...5 2 Card operating type 5 3 5 3 Communication port 5 4 DIP switch configuration 6 5 Configuration software instruction 6 5 1 Reader installation 6 5 2 Software connects to the device 7 5 3 Data output configuration instruction 8 5 4 Card SNR output configuration 9 5 5 Card data output configuration 10 5 5 1 Start data configuration 10 5 5 2 Continuous mode 10 5 5 3 Array mode 11 5 5 4 Extra key ad...

Страница 3: ...plement many type of uses The reader module supports the ISO14443A B compliant IC cards The output data could be UID and or card data 2 Characteristics PCD model NXP RC523 Working frequency 13 56MHz Supported standard ISO14443A ISO14443B SAM card slot 2 slots full function support ISO7816 only for ODM Power supply DC 5V 0 5V USB power supply Display 2 LED red yellow Buzzer Build in Interface USB H...

Страница 4: ...Mifare ISO14443A ISO14443B ISO7816 http www jinmuyu com Copyright 2003 2014 Jinmuyu Electronics Co LTD All rights reserved 3 19 3 Physical parameter and pin outs 3 1 Photo ...

Страница 5: ... ISO14443B ISO7816 http www jinmuyu com Copyright 2003 2014 Jinmuyu Electronics Co LTD All rights reserved 4 19 3 2 Dimension 3 3 Cards supported 3 3 1 ISO14443A Mifare One S50 4 T CL TYPE A dual interface CPU Card UID ...

Страница 6: ...on by PPS 3 4 Model available JMY609AU JMY609CU 3 5 Model rule 3 5 1 Model format 1 2 3 4 JMY 609 X X 1 company code 2 product series code 3 card operating type 4 communication port type 3 5 2 Card operating type A PCD is RC522 support ISO14443A and Mifare Class C PCD is RC523 support ISO14443A ISO14443B and Mifare Class 3 5 3 Communication port U USB HID Standards ...

Страница 7: ...nds on the software Working mode depends on SW2 SW2 Reader on the configuration mode Reader on the reading card mode SW3 SW4 5 Configuration software instruction 5 1 Reader installation The reader module interface is USB HID class The driver installation wills automatic process by OS User need not do anything except connect the reader Then check the attributes of USB Human Interface Device ...

Страница 8: ...u Electronics Co LTD All rights reserved 7 19 5 2 Software connects to the device Open the configuration tool Then click the Connect button Successfully connect as following The dialog box will prompt the supported card types Note MR761 and JMY609 have the same Configuration Software ...

Страница 9: ...uyu Electronics Co LTD All rights reserved 8 19 5 3 Data output configuration instruction Taking ISO14443A tag as an example set the output card number and card data As the picture the supported card is ISO14443A and output select is Card SNR Card Data Mifare S50 S70 and UltraLight ...

Страница 10: ...figuration Click SNR tab to set the Card SNR as following Card number order set Set MSB first or LSB first output Card Number format set Set HEX or DEC CapsLk set Set the letter of card number in Caps or lower case Extra key set After card number output select output key assignments 4 optional keys Tab Enter Down Arrow and Page Down and typing numbers ...

Страница 11: ...5 5 1 Start data configuration Click Mifare S50 S70 tab to set the card data output configuration Two modes Mode1 Mode2 can be select Select the key assignment in Every Block End and Data End as following 5 5 2 Continuous mode Name the start byte of the start block then output till to the end byte of the named end block as the chart If set the following parameters ...

Страница 12: ...me the start block and end block then start to output the data from the start byte to the end byte as the chart If set the following parameters Start sector 00 End sector 00 Start block 00 End block 02 Start byte 03 End byte 09 Then the output data is the red data in the chart 03 04 05 06 07 08 09 13 14 15 16 17 18 19 23 24 25 26 27 28 29 5 5 4 Extra key additional CapsLk setting Set CapsLk to con...

Страница 13: ...nd Set the output extra key after every block output ends Data end Set the output extra key after data output ends 5 6 Parameter downloads After finish all the configuration item click DownLoad to download the parameters if success as following If download success and then click Reset to restart the device After restart the computer and device disconnect Then the computer will re identify the devi...

Страница 14: ...ight 2003 2014 Jinmuyu Electronics Co LTD All rights reserved 13 19 5 7 Device working Once the computer re identifies the device it will only identify one device As following Then according to the set parameter the device will output the data after read success ...

Страница 15: ...utput data changed then need to reset the configuration parameters Please pull the DIP switch SW1 to OFF and SW2 to ON After the device power up and start user can normally setup the device parameter When parameter download finishes pull the DIP switch SW1 to ON then click Reset and restart the device the device will turn into working mode Setting steps 6 Application sample ...

Страница 16: ...Mifare S50 S70 data output E g as the chart the RED NUMBER stores in the Block 4 6 Set the System Config as following Not select Card SNR not output the card number Select Card data and Mifare S50 S70 Set the Mifare S50 S70 as following Select Mode 1 and set the continuous output mode Set Start sector 01 Start block 00 Start byte 07 ...

Страница 17: ...d Block 02 End Byte 06 Select data to output Select Key type Key A Set Key FF FF FF FF FF FF Set CapsLk to select the Capital letter output Set Every Block End the Key of Every Block End is None Key None Num 1 Set Data End the Key of Data End is Enter Num is 1 Key Enter Num 1 As the above setting the reader will output the Red data in the chart ...

Страница 18: ...ved 17 19 6 2 SRI4K data output As the chart there are 123456201008231234 stored in the Block4 6 Set the System Config as following Not select Card SNR not output the card number Select ISO14443B Card data and SRI512 2K 4K X4K Card Set the SRI512 2K 4K X4K Card as following Select Mode 1 Set Start Block 04 End Block 06 ...

Страница 19: ...s Co LTD All rights reserved 18 19 Start Byte 00 End Byte 00 Select CapsLk Capital output Set Every Block End the Key of Every Block End is None Key None Num 1 Set Data End the Key of Data end is Enter Num is 1 Key Enter Num 1 As the above setting the reader will output the Red data in the chart ...

Отзывы: