ELECTRICAL CONNECTION
CONTROLS
If hard-wiring to a fused spur, this work must be done by a
qualified electrician.
The electrical connection must be carried out in compliance with the
national regulations for electricians in force.
Before connecting the appliance to the electrical network, make sure
that the power is off.
Do not install the appliance if:
•
The power supply cable is damaged.
•
The appliance and / or the control boxes are damaged.
The appliance supply voltage is 230V.
Make sure the power supply complies with the appliance’s voltage.
Make sure that the power supply cable never comes into contact with
the hot surface of the appliance.
This appliance must be earthed and connected to a supply that is
earthed.
If the appliance is mounted in the bathroom or shower, the power line
must be equipped with an RCD with maximum rated current of 30mA.
In humid environments (bathrooms, kitchens, laundry rooms etc.) it is
very important that the electrical connection to the network is situated
at least at 25 cm from the floor.
Your heater should not be operated without a control system.
You must use either a wired or wireless thermostat depending on your
installation preference. If in doubt, ask professional qualified personnel.
This heater is
NOT equipped with a device to control the room
temperature. Do not use this heater in small rooms when they are
occupied by persons not capable of leaving the room on their own,
unless constant supervision is provided.
WiFi connection:
A WiFi hub is required to connect the thermostats to the app.
Wired Diagram:
Wireless Diagram:
Mains
Fused Spur
Thermostat
IR Panel
Mains
Fused Spur
IR Panel
Thermostat
RF Switch