background image

2

.

 

Safety

 a

nd

 In

staller

 

Responsibilities

   

 

2

.

1

 

Handling

 

and

 

Installing

 

Titan  solar

 

  

 

It

 

is critically important

 

that

 

safety

 

practices are

 

observed

 

when

 

installing

 

 

  Do not

 

throw

 

or roughly

 

handle

 

any Titan  solar components

.  

 

  Do not

 

bring

 

Titan  solar system into

 

contact

 

with

 

sharp

 

or heavy

 

objects

 

  Do not

 

modify Titan  solar

 

components in

 

any way

The

 

exchange

 

of bolts

drilling

 

of holes

bending

 

or

 

any

 

other physical

 

changes not described

 

in 

standard

 

installation

 

procedure

 

will

 

void the warranty

 

It  is

 

the

 

installer s

 

responsibility  to  verify

 

the

 

integrity  of  the  structure

 

to 

'

which

 

Titan   solar  components  is  fixed

Roofs  or  structures  with 

rotten

/

rusted

 

bearers

undersized

 

bearers

excessively

 

spaced  bearers

or  any

 

other

 

unsuitable

 

substructure

 

cannot

 

be

 

used  with  Titan

 

solar 

components

and

 

installation

 

on

 

such

 

structures  will  void

 

the

 

warranty

,

and

 

could result in death

 

or

 

serious

 

injury

.

 

2

.

2

 

Wind

 

and

 

Climate Design     

Determining  the  wind  pressures  applies  to  your  Titan  solar  system  install 

site,  taking  into  account  roof  shape  and  geographic  location.  Sufficient 

guidance  is  given  in  this  document,  but  you  may  wish  to  procure  a  copy 

of  these  standards.

 

  REMEMBER

 

average

 

wind

 

speeds  are  higher

 

for  structures  mounted 

closer  to  the

 

roof  perimeter  zone

 

(

edge

). 

Refer  to  Fixing  within

 

Roof 

'

Installation

 

Zone

 

for

 

more

 

information

)

'

 

  Make

 

sure

 

your

 

installation

 

complies  with  local

 

and  national  building 

codes

Take

 

into  account  relevant  design  parameters  (wind

 

speed

exposure

 

and  topographic

 

factor

when  determining

 

the

 

loading

 

for

 

the 

installation

 

  If  alternative

 

fasteners  are

 

used

 

to

 

fix

 

the

 

framing

 

to

 

the

 

roof  (assuming 

supplied  fasteners

 

are

 

unsuitable

 

for  any  reason

), 

all

 

screw

 

fasteners 

must  be  of  equal  or  greater  strength  to  those  supplied  with  your

Titan  solar  system  order. 

Caution

 

 

Installation of

 

this

 

product

 

is to be 

performed

 

only

 

by

 

professionally

 

trained

 

installers

.

 

Any

 

attempt

 

by

 

an

 

unqualified

 

person

 

to

 

install this 

product

 

could

 

result

 

in

 

death

 

or

 

serious

 

injury

.

 

Published Date 2015-10-20            4 / 21

JIANGYIN TITANERGY CO.,LTD.

Phone:0086-510-86610879        
F a x : 0 0 8 6 - 5 1 0 - 8 6 6 1 0 8 7 7
W e b : w w w. t i t a n e r g y. c o m          
M a i l : i n f o @ t i t a n e r g y. c o m

Model Name

TT-ADJUSTABLE TILT LEGS

Revision Number:01

Содержание TT-ADJUSTABLE TILT LEGS

Страница 1: ...JIANGYIN TITANERGY CO LTD SOLAR ROOF MOUNTING SYSTEM INSTALLATION MANUAL ModelName TT ADJUSTABLETILTLEGS...

Страница 2: ...0 11 Chapter Page General Information Safety and Installer Responsibilities Technical Specifications Tools for Installation Components Description System Overview Designing The Module Field Planning I...

Страница 3: ...ly So the D Modules is pre assembly with the clamp to save your install time Tilt in Align Up Fasten Easy installation four steps Titan solar s versatile design makes it suitable for a wide variety of...

Страница 4: ...ll site taking into account roof shape and geographic location Sufficient guidance is given in this document but you may wish to procure a copy of these standards REMEMBER average wind speeds are high...

Страница 5: ...04 635MPa 235MPa Stainless Steel A2 70 700MPa 450Mpa 3 4 Installation condition Roof slope 0 to 60 Building height Up to 20m Mounting structure Timber Roof type Flat steel System angle Flushed with th...

Страница 6: ...fixings Angle grinder For terracotta tile roof installation and angle grinder fitted with a continuous edge diamond tipped tile0cutting blade gloves hearing protection a face protection mask and a sui...

Страница 7: ...Fastened with a 6mm Allen key Standard pre assembly for the usual panels with thickness 30 35 40 46 50 57mm Fit on the roof Include 2pcs st6 3 80 wood screws Fit on the roof Include 2pcs st6 3 80 wood...

Страница 8: ...Screw Grounding Lug Fix the wire Material Cu Include 1pc M8 25 bolt 1pc M8 spring washer 1pc M8 OD18 lock washer 1pc nut 1pcM6 15 bolt Grounding Clip Electric Conduction Material Stainless steel Rubb...

Страница 9: ...1 2 of module height 4 Distance between roof connections horizontally Depending on the distance between rafters and on the static requirements please see the Chapter 8 on page 11 5 Distance between m...

Страница 10: ...on 8 3 Determine Roof Installation Roof Areas Titan solar system can be installed anywhere on a roof but fixing centers are required to be reduced at ridges and edges The diagram below shows the area...

Страница 11: ...nD Please use the following table to determine the base rail support spacing for for tin roof installations 2 Max PV panel length 2000mm Max panel weight 15kg m Tin Roof 10 a 15 Adjustable Racking Til...

Страница 12: ...or Up To 1970mm Long Panel 2Rails Max Support Spacing mm Installation Region A RegionB RegionC RegionD Height m Center Center Center Edge Center Edge Edge Edge Tin Roof 10 a 15 Adjustable Racking Tilt...

Страница 13: ...5 N A N A 20m 950 675 650 475 400 300 N A N A 5 m 1125 800 775 550 475 325 300 N A 10 m 925 675 625 450 425 300 N A N A 15m 850 600 575 425 375 N A N A N A 20m 800 575 550 375 325 N A N A N A Note for...

Страница 14: ...1200mm between the feet and 600mm of overhang at each end 8 6 Determine Roof Slope Titan solar system can be used for roof slope up to 60 degrees Please verify the Installation site roof slope should...

Страница 15: ...Phone 0086 510 86610879 Fax 0086 510 86610877 Web www titanergy com Mail info titanergy com 9 Installation 2 Fix the rear leg together with rubber pad to the rafter using two 6 80 wood screws Determin...

Страница 16: ...sher M8 antiskid washer and fixing nut to connect the rail with the front leg and the rear leg 4 TT Rail connect a Put the Rail Splice into the TT side channel of the Rail about TT 75mm then fasten th...

Страница 17: ...of rails 5 Repeat the above steps in accordance with the planned layout Telescopic Tubs 6 After finishing installation of whole system adjust the lengths of rear legs to adjust the tilt angle of panel...

Страница 18: ...Inter module clamp firmly against the already fixed module c Push the next module against the other side of the module inter clamp d Tighten the bolt 11 Installing the further rows of modules 9 Fixin...

Страница 19: ...e zip tie Published Date 2015 10 20 19 21 JIANGYIN TITANERGY CO LTD Phone 0086 510 86610879 Fax 0086 510 86610877 Web www titanergy com Mail info titanergy com Model Name TT ADJUSTABLE TILT LEGS Revis...

Страница 20: ...ng system Purchaser or where the Purchaser is an installer or builder who on supplies the Frame to another party to that other party End User This warranty is not transferable Where an End User wants...

Страница 21: ...Reason for change Document Author 01 2015 10 20 Initial Release Josie Published Date 2015 10 20 21 21 JIANGYIN TITANERGY CO LTD Phone 0086 510 86610879 Fax 0086 510 86610877 Web www titanergy com Mail...