Operation

J Flow Controls valves provide tight shut off when

used under normal conditions and in accordance

with J Flow Controls published pressure and

temperature chart. All valves are provided

standard with a locking device for either the open or

closed position. It is advised to never leave the

valve in a partially open position as seat life can be

reduced.

J Flow Controls DM4800 MS series are a ¼ turn

valve which closes in the clockwise direction. The

valves handle points at the flow direction, so when

the handle is in line with the pipeline, the valve is

open. Subsequently, when the handle is parallel to

the pipeline, the valve is closed. There is also a

notch on the valve stem indicating flow as well.

Make sure when installing an actuator that the

position of the valve matches the actuator.

Media which may solidify, crystallize or polymerize

should never be allowed to remain in the ball valve

cavies unless regular maintenance is performed.

Maintenance

J Flow Controls valves are designed to easily be

disassembled and reassembled in the field for easy

service. It is imperave that before compleng any

maintenance on a J Flow Controls valve, that the Safety

Precauons secon of this I&M is reviewed.

Ball valves normally do not require an internal lubricant

or roune maintenance once installed. Packing can be

adjusted if the valve has stem leakage or if the stem

seems loose. See the Troubleshoong secon of this

I&M for more informaon.

Internal maintenance by replacing the packing, seats,

seals, ball, or stem if any piece is damaged will require

disassembly (see Valve Disassembly).

Troubleshoong

STEM LEAKAGE

Examine the disk springs for damage. If they are in good

condion, then ghten the gland nut unl disk springs

are firmly compressed, then back nut off 1/16th of a

turn. If damaged, take apart the stem down to the

gland, fit new disk springs with their outer edges

touching, replace and reghten with the stem nut. Any

further maintenance will require the dismantling of the

valve.

LEAKAGE AT BODY JOINT

Check to see if the body connector bolts have been

ghtened. If loose, ghten body bolts according to the

torque requirements given in Table A. If valve sll leaks,

the valve has to be disassembled and body seals will

need replaced.

IN-LINE LEAKAGE

Posion the valve in the closed posion. If leakage

occurs while the valve is closed, ball sealant surface or

seat could be damaged and the valve will have to be

disassembled.

2

www.jflowcontrols.com

sales@jflowcontrols.com

J Flow Controls
4665 Interstate Dr.
Cincinna, OH 45246
Toll Free: 866-95-JFLOW (53569)
Local: 513-330-6354
Fax: 513-731-6939

DM 4800 Series MS Ball Valve

Installaon – Maintenance Manual

Document #: IM-DM4800 MS-01

Rev Date: 2010-02-01

Installaon & Maintenance for J Flow DM4800 Series Metal Seated Ball Valve

Содержание DM4800 SERIES

Страница 1: ...METAL SEATED BALL VALVE INSTALLATION MAINTENANCE MANUAL Document No DM4800 MS Date 2010 02 01 Version 1 PREPARED BY ATE _______________ D __________ REVIEWED BY DATE _______________ __________ APPROVED BY DATE _______________ __________ ...

Страница 2: ...revent damage to the seat due to contact with the balls edge Make sure to keep protec ve cover in place to prevent damage to the ball surface It is highly recommended that valves be stored indoors in a clean and dry environmentun lreadyforuse Safety Precau ons To prevent injury to yourself others or equipment make sure to read this sec on in its en rety before performing any installa on or opera o...

Страница 3: ...e once installed Packing can be adjusted if the valve has stem leakage or if the stem seems loose See the Troubleshoo ng sec on of this I Mformoreinforma on Internal maintenance by replacing the packing seats seals ball or stem if any piece is damaged will require disassembly seeValveDisassembly Troubleshoo ng STEM LEAKAGE Examine the disk springs for damage If they are in good condi on then ghten...

Страница 4: ...anufacturers parts are indicated by an asterisk on Table B by the part name numberedbytheexplodedviewattheendofthisI M Be sure to specify the exact valve part number to ensurethecorrectpartsareordered J Flow Controls does not take responsibility for incorrectlyorderedspareparts Valve Reassembly 1 Apply an adequate amount of lubricant that is compa ble with the media being handled around the Ball 4...

Страница 5: ...pare Parts List Item Qty Part Name Item Qty Part Name 1 1 Body 10 1 Gland Washer 2 2 End Cap 11 2 Disk Washer 3 2 Gasket 12 1 Stem Nut 4 1 Ball 13 1 Nut Stop 5 2 Seat 14 1 Spacer 5A 2 Disk Spring 15 1 Handle Nut 6 C F Bolts 16 1 Stop Bolt 7 1 Thrust Washer 17 1 Stop Nut 8 1 Stem 18 1 Handle 8A 2 Half Split Ring 19 2 Housing Seal 9 1 Stem Packing 20 2 Back up Seal 4 www jflowcontrols com sales jflowc...

Отзывы: