4
CONTROL PANEL
8.
LEDs indicating output voltage reading;
9.
Knob of output voltage adjustment (12V to 15V);
10.
LED indicating that the source is on;
11.
LED indicating that the dynamic output power control (
BOB STORM function
) is on.
USE THE BOB POWER SUPPLY FOR CHARGING BATTERIES
BOB STORM Power Supply and Charger
allow the output voltage to be
adjusted and can thus be used as a battery charger. With the aid of a multimeter,
simply adjust the output voltage by
14.4V
for a full load (it is not recommended to
keep 14.4V more than 12 hours). For battery charge maintenance (fluctuation), simply
adjust the output voltage to
13.8V
.
WARNING: BOB STORM Power Supply and Charger
are designed to prioritize
battery-without operation. When using the battery charging source, the output
voltage control is manual. Applying high voltages and currents for long periods of
time can damage batteries.
11
9
8
10
BOB STORM POWER SUPPLY AND CHARGER - INSTRUCTION MANUAL