JDx QUICK START GUIDE
6 | P a g e
Q S 8 7 9 8 3 8 , R E V A . 6
3.2.3
S
TREAMING
This command enables the JDx sensor to continuously transmit data out to the RS-485 bus at the bandwidth specified in
section 3.2.5. A value of 0 or 1 must be provided. The value of 0 turns off data streaming, while the value 1 enables data
streaming. This command is useful if the user wishes to not actively interrogate the JDx sensor for samples. Care should be
taken using this command when the JDx sensor is installed on a shared RS-485 bus.
Command Syntax
;<NodeID>,S,<1|0>
CRLF
or
:<NodeID>,S,<1|0>,<CRC16>
CRLF
Response Syntax
<NodeID>,S,<0=OFF, 1=ON>,Streaming,<CRC16>
CRLF
(Subsequent data points will adhere to the “V” command’s syntax, see section
Error!
Reference source not found.
)
Example Command
;009,S,1
CRLF
Example Response
009,S,1,Streaming,F465CRLF
009,V,7,+2.9175,-0.3806,+17.620,20,ACA9
CRLF
009,V,7,+2.9182,-0.3804,+17.618,21,7B87
CRLF
009,V,7,+2.9190,-0.3806,+17.618,22,E773
CRLF
Note
A Non-Volatile Save command is required to save the streaming setting to non-volatile
memory. This will ensure the parameter is recalled after a power cycle. Responses to the
commands are the same as the responses to the Get Value command.
Changing the baud or the output data rate of the device may interrupt the stream. If this
occurs, simply re-issue the command to start streaming with the new settings.