background image

General for A + B

Permanent Installation (fixed)

The heater can be installed horizontally or at a 

downward gradient of 15°.

1. The fixings are attached to the housing by 

use of 4 screws. The two spacing washers are  

placed between the housing and tubular frame 

(in the bottom hole).

2. Mark the hole positions. Drill out 4 holes to 

attach the fixing to the wall. Use M8 screws.

3. Now fix the heater in the top screws and 

attach the bottom screws.

Use of DELTA - List of signs

 

Off

 

Fan on

 

Half fan and half heat

 

Full fan and half heat

 

Full fan and full heat

DELTA fan heaters require no maintenance. 

However, it is recommended to clean the fan 

heater of dust by means of compressed air 

after long time of use or after use in dusty 

rooms.

Timer

To set time delay rotate the knob clockwise 

and then turn back anticlockwise to required 

setting.

Electrical Installation

Installation must be carried out with a 

multipoled contact breaker with a contact 

space measuring at least 3 mm per pole. Per-

manent installation must always be performed 

by an authorised electrician in accordance 

with current regulations. Only the electrician 

has knowledge of current regulations. The 

terminals are accessible if the screws and the 

plate on the right side are removed.

Preservation and storage

The units must be stored under the following 

conditions: 

• 

relative humidity < = 60%

• 

temperature > = 15°C

Disposal Instruction

Equipment containing electrical components 

may not be disposed of with household waste. 

It must be collected separately alon with other 

electrical or electronic waste, as required by 

local law.