SETTINGS AND OPERATIONS
4. PROGRAMMING ALARM LIMIT cont
•
Window 4: Here you can change the alarm limit for the UV current, check which level is program
med and change if necessary. Use the ”SET/RESET” button to move the cursor in the window,
change the digits by pressing the ”SELECT” button until the correct number is on the window.
As in exemlett above we would have 37A. Press the ”SET / RESET” button to proceed.
•
Window 5: Here is the value of the preprogrammed hysteresis value, this must not be changed!
Press the ”SET / RESET” button to proceed.
•
Window 6: (T1) Here you program a delay of outgoing alarm when it has detected a current loss,
Finder 71.51 is programmed with a delay of 10 seconds. This value should not be changed.
Press the ”SET/RESET” button to proceed.