32
[IO=2E0h; IRQ=3,4,5,6,7,9,10,11,12;].
Serial Port FIFO Mode
The optional settings are: [16-Byte FIFO]; [32-Byte FIFO]; [64-Byte FIFO];
[128-Byte FIFO].
►
Serial Port 4 Configuration
Press [Enter] to make settings for the following items:
Serial Port 4 Configuration
Serial Port
Use this item to enable or disable Serial Port (COM).
The optional settings: [Disabled]; [Enabled].
When set as [Enabled], the following items shall appear:
Device Settings
Change Settings
Use this item to select an optimal setting for Super IO Device.
The optional settings: [IO=2E8h; IRQ=10;]; [IO=3F8h; IRQ=3,4,5,6,7, 9,10,11,12;];
[IO=2F8h; IRQ=3,4,5,6,7, 9,10,11,12;]; [IO=3E8h; IRQ=3,4,5,6,7, 9,10,11,12;];
[IO=2E8h; IRQ=3,4,5,6,7,9,10,11,12;]; [IO=3E0h; IRQ=3,4,5,6,7, 9,10,11,12;];
[IO=2E0h; IRQ=3,4,5,6,7,9,10,11,12;].
Serial Port FIFO Mode
The optional settings are: [16-Byte FIFO]; [32-Byte FIFO]; [64-Byte FIFO];
[128-Byte FIFO].
OS Select For Serial Port
Serial port support for Windows or Linux.
The optional settings: [Windows]; [Linux].
WatchDog Reset Timer
Use this item to enable or disable WDT reset function.
The optional settings: [Disabled]; [Enabled].
When set as [Enabled], the following sub-items shall appear:
WatchDog Reset Timer Value
User can select a value in the range of [4] to [255] seconds when ‘
WatchDog
Timer Unit
’ set as [Sec]; or in the range of [4] to [255] minutes when ‘
WatchDog
Timer Unit
’ set as [Min].
WatchDog Reset Timer Unit
The optional settings: [Sec.]; [Min.].
WatchDog Wake-up Timer in ERP
This item support WDT wake-up while ERP function is set as [Auto].
The optional settings: [Disabled]; [Enabled].
When set as [Enabled], the following sub-items shall appear:
WatchDog Reset Timer Unit
The optional settings: [Sec.]; [Min.].
WatchDog Timer Value in ERP
User can select a value in the range of [10] to [4095] seconds when ‘
WatchDog
Timer Unit
’ set as [Sec]; or in the range of [1] to [4095] minutes when ‘
WatchDog
Timer Unit
’ set as [Min].
ATX Power Emulate AT Power
This item support Emulate AT power function, MB power On/Off control by power