Change oil in pump after first 50 hours of operation and 
every 500 hours of operation after that. With the pump 
warm from operation, remove plug on bottom of pump 
and drain oil into suitable container. Replace plug. Fill to 
approximately half-way on the sight-glass with SAE 15W-
40 Mineral non-detergent oil using the checking procedure. 
At 1000 hours of use (less in severe use conditions) the unit 
should be taken to a Jetwave Independent Service Center 
for pump seal and valve service.

Preparing Pump for Cold Weather Storage

If the unit will be stored under conditions where the 
temperature is near or below 0°C, the unit must be properly 
prepared. If water freezes in the pump, it can damage it.
After the tank is drained (if applicable), remove the hose 
from the water inlet filter. Open all valves in the system and 
use compressed air to force any water out of the system. 
This can also be used to remove water from the hoses.

Machine Storage

Store the unit in a well ventilated area protected from the 
weather elements. Keep the machine in a locked area 
that is out of reach of children and people unfamiliar with 
High Pressure Cleaners. This machine can cause serious 
injury in the hands of untrained users. See Maintenance 
section for information on cold weather storage. See 
engine operator’s manual for specific information on engine 
storage.

Service And Repair

WARNING

Improper service or repair can make machine unsafe 
to operate.

The “Maintenance Instructions” will take care of most 
of the service needs of this machine. Any problems not 
addressed by this section should only be handled by an 
authorized Jetwave service technician.
Unit should be taken to a Jetwave Independent Service 
Center or returned to the factory.
For information on your nearest Jetwave Independent 
Service Center or any service or repair questions:
•  Contact your local Jetwave distributor.
•  Visit jetwavegroup.com.au/find-a-dealer/ to find your 

local Jetwave contact point.

•  Contact Jetwave Technical Service Department at 

[email protected] or call (08) 8371 3599

Disposal

Parts of the unit contain valuable materials and can be 
recycled. There are companies that specialize in recycling 
that may be found locally. Dispose of the components in 
compliance with all applicable regulations. Contact your 
local waste management authority for more information.

Содержание Raptor

Страница 1: ...r which is located on nameplate UNIT SERIAL NO ENGINE SERIAL NO PURCHASE DATE Cold Water Petrol Driven WARNING Read this Operator s Manual carefully before using this machine Failure to understand and follow the contents of this manual may result in electrical shock fire and or serious personal injury READ CAREFULLY ENGLISH VERSION ...

Страница 2: ...nt Description Specifications Standard Equipment Machine Assembly Operation Engine Oil Pump Oil Wheels Pre Operation Inspection Machine and Work Area Set Up Water Supply Operating Instructions Transportation and Storage Maintenance Instructions Cleaning Engine Battery Pump Lubrication Maintenance Preparing Pump for Cold Weather Storage Optional Equipment Machine Storage Service And Repair Disposal...

Страница 3: ... shock fire and or serious injury SAVE THESE INSTRUCTIONS Work Area Safety Keep work area clean and well lit Cluttered benches and dark areas invite accidents Do not operate power tools in explosive atmospheres such as in the presence of flammable liquids gases or dust Power tools create sparks which may ignite the dust or fumes Keep bystanders children and visitors away while operating a power to...

Страница 4: ... goggles protective clothing respirators head protection hearing protection and steel toed footwear Practice good hygiene Use hot soapy water to wash hands and other body parts exposed to drain contents after handling or using drain cleaning equipment Do not eat or smoke while operating or handling high pressure cleaning equipment This will help prevent contamination with toxic or infectious mater...

Страница 5: ...ssure Cleaner Machine is a portable unit designed to use a combination of water pressure and flow to clean different surfaces from dirt grease grime Water is pumped through the high pressure plunger pump at increased pressure and flow allowing water to be used at such high pressure to remove dirt and grime from surfaces The Raptor High Pressure Cleaner is equipped with an gasoline Honda engine to ...

Страница 6: ...Maintenance section Wheels Typically the unit is boxed and shipped without wheels assembled Wheels Axle Locking Collar are found within the box To assemble the wheels slide axle through axle location hole slide wheels on each side find centerline and proceed to install locking collar each side with 4mm Allen key tool Pre Operation Inspection WARNING Before each use inspect your pressure cleaner an...

Страница 7: ...a colorless odorless poison gas Breathing carbon monoxide can cause nausea fainting or death Do not start and run engine in an enclosed area even if doors and windows are open Only operate outside Set up the unit and work area according to these procedures to reduce the risk of injury from high pressure water chemical burns infections carbon monoxide and other causes and prevent jetter damage 1 Ch...

Страница 8: ...putation do not direct spray at people or animals do not operate jetter above pressure rating or 60 C inlet water temperature This increases the risk of injury including burns and damage to the unit One person must control the unit process and water flow Always use appropriate personal protective equipment while handling and using high pressure cleaning equipment Appropriate personal protective eq...

Страница 9: ...e orifices with the nozzle cleaning tool Ensure correct nozzle orifice size is used and no signs of excessive wear are evident Activate trigger and run the unit to remove air or debris from the system Turn the unit OFF before removing or attaching the lance nozzle 6 Assume a proper operating position Be sure you can control the ON OFF action of a water control valve Do not turn the valve ON yet In...

Страница 10: ...al system Do not clean with pressure washer Wipe the unit down with a damp cloth Engine Maintain the engine as directed in the engine operator s manual supplied with the unit Battery To change battery if applicable 1 Unclip strap if applicable holding battery box top on remove top 2 Disconnect ground cable connection first followed by positive cable connection 3 Remove battery 4 Reverse procedure ...

Страница 11: ...ked area that is out of reach of children and people unfamiliar with High Pressure Cleaners This machine can cause serious injury in the hands of untrained users See Maintenance section for information on cold weather storage See engine operator s manual for specific information on engine storage Service And Repair WARNING Improper service or repair can make machine unsafe to operate The Maintenan...

Страница 12: ...ton packing Dirty filter Check clean or replace Check that all hoses and fittings are airtight Check and replace Check and clean Presence of water in oil High humidity in air Piston packing or oil seal worn Water entering through breather Check and change oil twice as often Check and replace Water dripping from pump Piston packing worn Piston guide o rings worn Check and replace Check and replace ...

Страница 13: ...13 RAPTOR MANUAL HIGH PRESSURE CLEANER Hour Meter Reading Date Maintenance Performed Service Agent Maintenance Log ...

Страница 14: ...14 RAPTOR MANUAL HIGH PRESSURE CLEANER Notes ...

Страница 15: ......

Страница 16: ...jetwavegroup jetwave group jetwavegroup 72 74 Richmond Road Keswick 5035 Adelaide South Australia AU 61 8 8371 3599 sales jetwave com au jetwave com au jetwavegroup jetwave group ...

Отзывы: