Jetwave Hornet G2 Series Скачать руководство пользователя страница 7

7

HORNET G2 MANUAL -  HIGH PRESSURE CLEANER

4.  Inspect the pressure cleaner nozzle orifices for any 

damage or blockage. Blockages can be cleaned with 
a nozzle cleaning tool. Use care not to enlarge nozzle 
orifices while cleaning. Damaged nozzles or nozzles 
with enlarged orifices can decrease unit performance 
and should be replaced. 

5.  Inspect the hoses, connectors and fittings for wear and 

damage. If there are any kinks, cracks, breaks or wear 
through the outer jacket of the hose or other damage, 
do not use the hose. Damaged hoses can burst or 
leak high pressure water and cause serious injury. 
Replacement hoses and fitting should be rated at or 
higher than the unit pressure rating. 

6.  Inspect and maintain the engine per the engine 

operator’s manual. 

7.  Check engine fuel level. If needed, add unleaded 

gasoline for Hornet G2 Petrol or add diesel for Hornet 
G2D. See engine operator’s manual for requirements. 
Use caution when handling fuel. Work in a well 
ventilated area. Never fill the tank while unit is running, 
do not overfill tank and do not spill fuel. Make sure tank 
cap is securely closed. 

8.  Check the oil level(s) in the pump and gear box through 

the sight glass and add oil if needed (see Maintenance 
Instructions section). Inspect Engine as directed in the 
engine operator’s manual.

Machine and Work Area Set-up

Always wear safety glasses, gloves and other 
appropriate protective equipment when setting up 
your pressure cleaner. Rubber soled, non-slip shoes 
can help prevent slipping on wet surfaces.

Engines produce carbon monoxide, a colorless, 
odorless poison gas. Breathing carbon monoxide 
can cause nausea, fainting or death. Do not start and 
run engine in an enclosed area, even if doors and 
windows are open. Only operate outside.
Set-up the unit and work area according to these 
procedures to reduce the risk of injury from high 
pressure water, chemical burns, infections, carbon 
monoxide and other causes, and prevent unit 
damage. 

1.  Check work area for:

•  Adequate lighting.
•  Flammable liquids, vapors or dust that may ignite. 

If present, do not work in area until sources have 
been identified and corrected. The machine is not 
explosion proof and can cause sparks.

•  Clear, level, stable dry place for machine and 

operator.

•  If needed, remove the water from the work area. 

Wood or other coverings may need to be put 
down.

•  Unit location that is in a well ventilated outdoor 

area. Do not place the unit indoors, even with 
doors and windows open. Unit can be located 
remotely from the point of use.

•  Suitable water supply. Clear path to transport the 

unit to the set up location.

2.  Inspect the surface to be cleaned, and make sure no 

materials or elements are in the way of the unit.

3.  Determine the correct equipment for the application. 
4.  Make sure all equipment has been properly inspected.
5.  Evaluate the work area and determine if any barriers 

are needed to keep bystanders away. Bystanders 
can distract the operator. If working near traffic, erect 
cones, signs or other barriers to alert drivers.

6.  Take the unit to the well-ventilated outdoor work area 

along the clear path. See Transportation Section. 
Be aware of possible slip hazards. Wear appropriate 
footwear to help prevent slips.

WARNING

Figure.5 - Hornet G2 Water Filter

Содержание Hornet G2 Series

Страница 1: ...ct serial number which is located on nameplate UNIT SERIAL NO ENGINE SERIAL NO PURCHASE DATE Cold Water Petrol or Diesel Driven WARNING Read this Operator s Manual carefully before using this machine...

Страница 2: ...Specifications Standard Equipment Machine Assembly Operation Engine Oil Pump Gearbox Oil Wheels Pre Operation Inspection Machine and Work Area Set Up Water Supply Operating Instructions Transportatio...

Страница 3: ...shock fire and or serious injury SAVE THESE INSTRUCTIONS Work Area Safety Keep work area clean and well lit Cluttered benches and dark areas invite accidents Do not operate power tools in explosive a...

Страница 4: ...personal protective equipment PPE includes safety glasses and gloves and may also include equipment such as latex or rubber gloves face shields goggles protective clothing respirators head protection...

Страница 5: ...of water pressure and flow to clean different surfaces from dirt grease grime Water is pumped through the high pressure plunger pump at increased pressure and flow allowing water to be used at such h...

Страница 6: ...heels Typically the unit is boxed and shipped with wheels assembled Wheels Axles Locking Collar are found within the box To assemble the wheels slide axles through axle location hole slide wheels on e...

Страница 7: ...ngines produce carbon monoxide a colorless odorless poison gas Breathing carbon monoxide can cause nausea fainting or death Do not start and run engine in an enclosed area even if doors and windows ar...

Страница 8: ...ipment for the work environment Never operate the unit without the hose attached to a spray gun Hose can whip causing striking injuries and spray can penetrate skin and cause serious injury High press...

Страница 9: ...here is adequate water flow to the unit Turn the unit OFF Remove the nozzle and clean the orifices with the nozzle cleaning tool Ensure correct nozzle orifice size is used and no signs of excessive we...

Страница 10: ...ne or electrical system Do not clean with pressure washer Wipe the unit down with a damp cloth Engine Maintain the engine as directed in the engine operator s manual supplied with the unit Battery To...

Страница 11: ...in the pump it can damage it After the tank is drained if applicable remove the hose from the water inlet filter Open all valves in the system and use compressed air to force any water out of the sys...

Страница 12: ...ton packing Dirty filter Check clean or replace Check that all hoses and fittings are airtight Check and replace Check and clean Presence of water in oil High humidity in air Piston packing or oil sea...

Страница 13: ...13 HORNET G2 MANUAL HIGH PRESSURE CLEANER Hour Meter Reading Date Maintenance Performed Service Agent Maintenance Log...

Страница 14: ...14 HORNET G2 MANUAL HIGH PRESSURE CLEANER Notes...

Страница 15: ......

Страница 16: ...jetwavegroup jetwave group jetwavegroup 72 74 Richmond Road Keswick 5035 Adelaide South Australia AU 61 8 8371 3599 sales jetwave com au jetwave com au jetwavegroup jetwave group...