Jetwave Hornet 202 Скачать руководство пользователя страница 9

9

HORNET 251 MANUAL -  HIGH PRESSURE CLEANER

7.  With the wand pointed in a safe direction, squeeze the 

wash wand trigger to reduce pressure and allow the 
engine to be started. Following the starting instructions 
supplied in the engine manual, start the engine. Set 
the throttle to the full open position. Allow the engine 
to warm up. Release the trigger soon after the engine 
starts.

8.  With the wand pointed in a safe direction, squeeze 

the wash wand trigger. If applicable; turn the unloader 
valve while monitoring the pressure gauge to adjust 
the pressure as desired. Do not exceed the machine 
pressure rating. Release the wash wand trigger.

9.  (If Applicable) Apply choke before starting.
10.  Proceed to start engine.
11.  Open the water control valve (high pressure gun). 

Following the starting instructions supplied in the 
engine operator manual, start the engine. Set the 
throttle to the full open position (If Applicable). Confirm 
that water flows freely through the nozzle. Close the 
trigger on the high pressure gun. When the water 
control valve is closed and the unit is running, the 
unloader valve will recirculate water back to the pump 
head or tank (If Applicable). Allow the engine to warm 
up.

6.  If needed, turn the unloader valve while monitoring 

the pressure gauge on the unloader valve to adjust 
the pressure as desired (If Applicable) (clockwise to 
increase pressure, counter-clockwise to decrease 
pressure). Do not exceed the machine pressure rating. 
Do not force the unloader valve or use wrenches or 
tools to turn. This will damage the unloader valve.

If the unit will not generate the rated pressure or is erratic
•  Make sure the engine throttle is properly adjusted to 

the full open position.

•  Turn unloader valve clockwise to increase pressure. Do 

not force.

•  Inspect system for leaks. Use caution during inspection 

to prevent injury. If leaks are found, shut unit OFF 
before fixing.

•  Turn the unit OFF. Check the inlet hose and filter and 

make sure that they clear of debris.

•  Make sure there is adequate water flow to the unit.
•  Turn the unit OFF. Remove the nozzle and clean the 

orifices with the nozzle cleaning tool.

•  Ensure correct nozzle orifice size is used and no signs 

of excessive wear are evident.

•  Activate trigger and run the unit to remove air or debris 

from the system. Turn the unit OFF before removing or 
attaching the lance/nozzle.

6.  Assume a proper operating position.
•  Be sure you can control the ON/OFF action of a water 

control valve. Do not turn the valve ON yet. In case of 
emergency you must be able to turn off water flow.

•  Be sure that you have good balance and do not have 

to overreach.

•  You must be able to place one hand on the gun at all 

times to control and support the lance.

This operating position will help to maintain control of the 
gun and lance.

Pressure Washer operation

1.  When using as a pressure washer use both hands 

to grip and direct the wash wand for greater control. 
Never direct the wash wand at people. High pressure 
fluid can inject under skin resulting in serious injury. 
Never direct wash wand at electrical equipment or 
wiring to reduce the risk of electrical shock.

2.  Control the flow of water with the trigger. Use care 

when using the pressure washer. Holding the nozzle 
too close to a surface can damage it. Test a small, 
inconspicuous area to confirm the settings work as 
desired.

3.  Do not allow the jetter to run for extended period of 

time with the trigger OFF. When the trigger is OFF, 
water recirculates and it causes the water to heat up.

4.  Once pressure washing is complete, release the trigger 

and turn OFF the engine as directed in the engine 
manual. Squeeze the trigger and ensure all water 
control valves are also in open position to release 
system pressure. Never leave the system pressurized.

Machine Shut Down Procedure

1.  When high pressure cleaning task is complete, release 

high pressure trigger.

2.  Return to the unit controls.
3.  Idle down unit RPMs via throttle control (if applicable)
4.  Proceed to power down the engine via kill switch or 

key switch (if applicable). Refer to engine operator 
manual.

5.  Turn water supply OFF.
6.  Release system back pressure by pressing the trigger 

on the spray gun (if applicable).

7.  Disconnect high and low pressure hoses and coil the 

assembly for safety and proper storage.

Содержание Hornet 202

Страница 1: ...ain product serial number which is located on nameplate UNIT SERIAL NO ENGINE SERIAL NO PURCHASE DATE Cold Water Petrol Driven WARNING Read this Operator s Manual carefully before using this machine F...

Страница 2: ...n Specifications Standard Equipment Machine Assembly Operation Engine Oil Pump Gearbox Oil Wheels Pre Operation Inspection Machine and Work Area Set Up Water Supply Operating Instructions Transportati...

Страница 3: ...c shock fire and or serious injury SAVE THESE INSTRUCTIONS Work Area Safety Keep work area clean and well lit Cluttered benches and dark areas invite accidents Do not operate power tools in explosive...

Страница 4: ...cleaning equipment Appropriate personal protective equipment PPE includes safety glasses and gloves and may also include equipment such as latex or rubber gloves face shields goggles protective clothi...

Страница 5: ...ine is a portable unit designed to use a combination of water pressure and flow to clean different surfaces from dirt grease grime Water is pumped through the high pressure plunger pump at increased p...

Страница 6: ...ection Wheels Typically the unit is boxed and shipped without wheels assembled Wheels Axles Locking Collar are found within the box To assemble the wheels slide axles through axle location hole slide...

Страница 7: ...onoxide a colorless odorless poison gas Breathing carbon monoxide can cause nausea fainting or death Do not start and run engine in an enclosed area even if doors and windows are open Only operate out...

Страница 8: ...ment for the work environment Never operate the unit without the hose attached to a spray gun Hose can whip causing striking injuries and spray can penetrate skin and cause serious injury High pressur...

Страница 9: ...unit OFF Remove the nozzle and clean the orifices with the nozzle cleaning tool Ensure correct nozzle orifice size is used and no signs of excessive wear are evident Activate trigger and run the unit...

Страница 10: ...an with pressure washer Wipe the unit down with a damp cloth Engine Maintain the engine as directed in the engine operator s manual supplied with the unit Battery To change battery if applicable 1 Unc...

Страница 11: ...es in the pump it can damage it After the tank is drained if applicable remove the hose from the water inlet filter Open all valves in the system and use compressed air to force any water out of the s...

Страница 12: ...ston packing Dirty filter Check clean or replace Check that all hoses and fittings are airtight Check and replace Check and clean Presence of water in oil High humidity in air Piston packing or oil se...

Страница 13: ...13 HORNET 251 MANUAL HIGH PRESSURE CLEANER Hour Meter Reading Date Maintenance Performed Service Agent Maintenance Log...

Страница 14: ...14 HORNET 251 MANUAL HIGH PRESSURE CLEANER Notes...

Страница 15: ......

Страница 16: ...jetwavegroup jetwave group jetwavegroup 72 74 Richmond Road Keswick 5035 Adelaide South Australia AU 61 8 8371 3599 sales jetwave com au jetwave com au jetwavegroup jetwave group...