Jetvent Fans JVEC-LP Скачать руководство пользователя страница 6

 

jetventfans.com 

 

 JetVent is a Registered Trademark 

 

Contents 

 

PRE-INSTALLATION ...................................................................................................................................................................... 1

 

PARTS ENCLOSED ......................................................................................................................................................................... 1

 

JETVENT FANS SPECIFICATIONS ................................................................................................................................................... 2

 

LAYOUT ........................................................................................................................................................................................ 2

 

INSTALLATION .............................................................................................................................................................................. 3

 

STEP 1: HANGING THE FAN ..................................................................................................................................................... 3

 

STANDARD INSTALLATION METHOD ................................................................................................................................... 3

 

SOUND SENSATIVE INSTALLATION ...................................................................................................................................... 3

 

JetVent Fans Do’s and Don’ts: ............................................................................................................................................. 4

 

STEP 2: WIRING FAN MAINS .................................................................................................................................................... 5

 

STEP 3: WIRING FAN SPEED CONTROL SIGNAL ....................................................................................................................... 5

 

OPTION 1 - Wiring 10k Ohm Potentiometer ........................................................................................................................ 6

 

OPTION 2 - Wiring 0–10 Volt DC Analog Signal ................................................................................................................... 6

 

OPTION 3 - Wiring 4-20mA Current Signal .......................................................................................................................... 7

 

OPTION 4 - Wiring MODBUS Control Signal ........................................................................................................................ 7

 

Fieldbus/Modbus Communication Cabling ........................................................................... 

Error! Bookmark not defined.

 

STEP 4: SENSOR WIRING ....................................................................................................................................................... 10

 

SENSOR 1 ........................................................................................................................................................................... 10

 

SENSOR 2 ........................................................................................................................................................................... 10

 

STEP 5: FINAL INSTALLATION STEP ........................................................................................................................................ 11

 

 

Содержание JVEC-LP

Страница 1: ...etVent is a Registered Trademark Installation Guide Models JVEC LP JVEC SP JVEC HP May be covered by the following United States and International Patents D631148S 138172 001790452 001 338608 and othe...

Страница 2: ...al framing member that has sufficient strength to support at least three times the hanging weight of the fan If uncertain a certified engineer or architect should conduct an analysis of the installati...

Страница 3: ...disconnected from power to avoid accidental restart CAUTION The Zoo Fans product warranty will not cover equipment damage or failure that is caused by improper installation operation or use ATTENTION...

Страница 4: ...ois minutes s est coul e depuis le d branchement de cela AVERTISSEMENT Pour r duire le risque d incendie de choc lectrique ou de blessures corporelles montez le ventilateur directement sur un l ment d...

Страница 5: ...une panne de courant ou un d branchement de l alimentation principale un red marrage automatique du ventilateur se fait lorsque l alimentation est restaur e Attendez que le ventilateur arrive un arr...

Страница 6: ...STALLATION 3 JetVent Fans Do s and Don ts 4 STEP 2 WIRING FAN MAINS 5 STEP 3 WIRING FAN SPEED CONTROL SIGNAL 5 OPTION 1 Wiring 10k Ohm Potentiometer 6 OPTION 2 Wiring 0 10 Volt DC Analog Signal 6 OPTI...

Страница 7: ...requirements may vary depending on the location and application of the equipment The elements of a successful installation consist of 1 Good layout of fans wiring and controls 2 Hanging the fans where...

Страница 8: ...ich are Ceiling height as well as the overall volume of air the fans need to move in order to achieve the targeted level for turnover of air in the facility every hour The availability of a sturdy and...

Страница 9: ...unts close up of yellow box Illustrated on the right STANDARD INSTALLATION METHOD For standard installation use an 8mm Lag bolts directly to the mounting points SOUND SENSATIVE INSTALLATION For sound...

Страница 10: ...Page 4 JETVENT FANS DO S AND DON TS...

Страница 11: ...must be made according to Illustration 8 the wiring diagram below Illustration 8 Wiring Fan Mains Diagram STEP 3 WIRING FAN SPEED CONTROL SIGNAL The JetVent Fans are factory programmed with one of the...

Страница 12: ...en Red 24 VDC 10 VDC Din1 Din2 RSA D RSB D GND Ain1 0 10V Ain1 4 20m A Ain2 0 10V Ain2 4 20m A Aout GND Fault NO Fault COM Brown Red Grey Pink Black White Turquoise Yellow Green Violet Red Black Orang...

Страница 13: ...d Blue Green Red 24 VDC 10 VDC Din1 Din2 RSA D RSB D GND Ain1 0 10V Ain1 4 20m A Ain2 0 10V Ain2 4 20m A Aout GND Fault NO Fault COM Brown Red Grey Pink Black White Turquoise Yellow Green Violet Red B...

Страница 14: ...WIRING CONFIGURATION END OF LINE X3 END OF LINE X8 Maximum communication wiring length is 500m before a Modbus repeater is required Separate conduit should be used for power and communications cable...

Страница 15: ...ive length 20cm The shield must NEVER be connected to an electrical protective earth point Termination Communication cables must be terminated with 120 ohm watt resistors connected between A and B ter...

Страница 16: ...Turquoise Yellow Green Violet Red Black Orange Blue Red Blue Green Red 24 VDC 10 VDC Din1 Din2 RSA D RSB D GND Ain1 0 10V Ain1 4 20m A Ain2 0 10V Ain2 4 20m A Aout GND Fault NO Fault COM Brown Red Gr...

Страница 17: ...ons where a fire alarm will enable or disable fans please use this wiring diagram Brown Red Grey Pink Black White Turquoise Yellow Green Violet Red Black Orange Blue Red Blue Green Red 24 VDC 10 VDC D...

Страница 18: ...Copyright 2018 ZOO Fans Inc All Rights Reserved Rev 20192901 BROUGHT TO YOU BY THE FAN EXPERTS AT 1650 38th St Suite 201W Boulder CO 80301 303 557 1852 zoofans com...