Version Update – March 2003
NANO-C, V3.00 to V3.01
6
Jetter AG
2.2 Register for Milliseconds
Register 2037: Timer for Milliseconds
Function Description
Read
present value of the timer for milliseconds
Value after reset: 0
Write Illegal
Value range
0 – 65535
The NANO-C will increment the millisecond timer by one every millisecond. It will start
automatically after switching on the NANO-C. Stopping the timer is not possible.
2.3 System Bus
2.3.1 Further modules
Besides modules produced by Jetter AG, modules produced by other manufacturers can
also be connected to the system bus of the NANO-C. In general, these modules are
handled like a JX-SIO module.
The following modules are supported by a NANO-C of the software version 3.01:
Further modules at the system bus
Manufacturer Product
Designation
Bürkert GmbH & Co. KG Valve terminal type 8640
/
Bürkert_BI_100_user information
Festo AG & Co.
CPV10-GE-CO2-8
CPV14-GE-CO2-8
CPV18-GE-CO2-8
CPX-FB14
/
Festo_BI_100_user information
SMC Pneumatik GmbH
SI-unit EX120 - SCA1
SI-unit EX121 - SCA1
SI-unit EX122 - SCA1
/
SMC_BI_100_user information
The modules produced by other manufacturers are recognized and commissioned
automatically. Another commissioning software will not be needed. For connecting these
modules, please consider the operating instructions of the respective manufacturers.
In addition, user information has been provided by Jetter AG, in which the operation of
these modules being connected to the Jetter system bus is described.