Description of Connections
Pin
X18 Bus In
X18.1
CMODE0
X18.2
CL
X18.3
GND
X18.4
CMODE1
X18.5
TERM; internally bridged
by X18.3
X18.6
Unused
X18.7
CH
X18.8
Unused
X18.9
Do not connect
Pin
X19 Bus Out
X19.1
CMODE0
X19.2
CL
X19.3
GND
X19.4
CMODE1
X19.5
TERM
X19.6
Unused
X19.7
CH
X19.8
Unused
X19.9
Do not connect
Pin
X10 Supply Voltage
X10.DC24V Supply voltage
X10.0V
Reference potential
Important!
For deactivating the internal bus terminating
resistor, you must short-circuit pin X19.5 with