Jetter AG
Programming | 7
JVM-104-O08 User Manual
28 / 44
Parameter
Description
Value
Reboot
System restart
True
The system is shut down
False
Return value
This function transmits the following return values to the higher-level program.
Return value
Description
0
OK
-1
Ignition is still switched on
INFO
If the ignition is still switched on, the device will not be switched off. However, the
HMI can be restarted. Such a restart is carried out irrespective of the fact that the
ignition is on.
If you switch off the vehicle's ignition, the sample program executes the
Shut-
down()
function after a delay of 3 seconds. The
Reboot
parameter for the
Shutdown()
function has the value
false
. This means that the device will switch
off.
Var
Ignition: Int
At
%VL
361100
;
End_Var;
Task
Ign
Autorun
Loop
When
Ignition
Continue;
Delay(
3000
);
Shutdown(
False
);
End_Loop;
End_Task;
INFO
For more information on this subject, refer to JetSym online help.
7.6 Operating system update
Jetter AG are continuously striving to enhance the operating systems of their
products. Enhancing means adding new features, upgrading existing functions
and fixing bugs. Current OS files are available for download on our homepage in
the
Downloads
area of the respective product.
More information on this subject is available on our website.
Start | Jetter - We automate your success.
Transfer options
There are several options to transfer the OS file to the device:
■
With the programming tool JetSym
■
Via JetEasyDownload