JetMove 204-480
13 Safe Standstill (Option)
Jetter AG
99
13.5.1 Control variants for "Safe Standstill"
• Controlling via safety relays
• OSSD control
OSSD:
O
utput
S
ignal
S
witching
D
evice
Controlling the inputs "Safe Standstill" with test pulses for recognizing short
circuits, shorts between contacts, or shunts of the control cable. The test pulses
have a length of 1 ms and a repetition frequency of 100 Hz. At applying a control
logic with OSSD signals, errors (e.g. short circuits or shorts between contacts)
can be recognized by the logic circuit itself, and they will lead to switching off both
signal ways.
The following signal waveforms are accepted by the OSSD signals without triggering
an error message:
Fig.: 24: Example: OSSD-signal waveform, single pulse
Fig.: 25: Example: OSSD-signal waveform, dual pulse
24 V
0 V
<1.3 ms
>7.0 ms
24 V
0 V
<0.8 ms
>7.0 ms
<0.8 ms
0.5 ms
Содержание JM-204-480
Страница 1: ...User Manual JM 204 480 Digital Servo Amplifier 60870618 We automate your success...
Страница 34: ...4 Physical Dimensions 34 Jetter AG...
Страница 42: ...5 Technical Data 42 Jetter AG...
Страница 43: ...JetMove 204 480 Jetter AG 43 6 Drive Controller Structure Fig 7 Block diagram of drive controller structure...
Страница 82: ...82 Jetter AG...
Страница 86: ...86 Jetter AG...
Страница 106: ...13 Safe Standstill Option 106 Jetter AG...
Страница 116: ...15 Ordering Information 116 Jetter AG...
Страница 117: ...JetMove 204 480 Appendices Jetter AG 117 Appendices...
Страница 118: ...Appendices 118 Jetter AG...