7 Description of Connections
78
Jetter AG
Incremental encoder cable
JetMove 108
(male SUB-D connector
X61)
Shield
Specification
of the cable
Encoder signal:
5 V differential signal
or
5 V single-ended
Maximum cable length:
100 m
Attaching screws must
have a metric thread!
Connect shield with the
greatest possible surface
area!
Use metallized housing
only!
Pin
Signal
2
K1+
12
K1-
3
K2
13
K2-
7
K0
8
K0-
1
Voltage output
(5 volts)
I
max
= 350 mA
6
Voltage output
(24 volts)
I
max
= 300 mA
11
0 V
1
6
11
5
10
15
Shield
Note 1!
Supply v5 V at the JetMove 108:
Due to conduction loss, a lower voltage might be supplied to the encoder.