Jetter AG
Connecting alphanumeric HMIs | 2
Application-oriented manual – Control of alphanumeric HMIs (LCD) and printers
11
Number
Part
Description
1
Terminal X11
Serial interface of the controller
2
Shield
Use shielded cables both ends of
which are connected to the metallized
housing of the connector.
3
Power supply
In a multi-display setup, each HMIs
requires individual power supply.
4 ... 7
Terminals
HMI interfaces
Cable specification
The following minimum requirements apply to cable sets:
Parameter
Description
Core cross-sectional area
0.14 mm
2
Maximum cable length
100 m
Shield
Complete, not paired
2.4 Interface cable assembly no. 192 xM
The interface cable assembly 192 xM connects the following types of HMIs to the
controller:
■
LCD 16
■
LCD 23
■
LCD 25
■
LCD 27
■
LCD 34
■
LCD 110
Male connector
specification
(controller end)
Parameter
Description
Type
8-pin male MiniDIN connector
Manufacturer
KYCON
Item
KMDLA - 8P
Recommended core
cross section
0.051 mm
2
... 0.128 mm
2
Male connector
specification
(HMI end)
Parameter
Description
Type
15-pin male SUB-D connector in metallized hous-
ing (quality grade 3)
Manufacturer
Various
Recommended core
cross section
0.128 mm
2
... 0.25 mm
2