Jetter AG
469
JC-120MC
Programming
Register numbers
The registers of each interface are combined into one register block. The
basic register number of this block is dependent on the controller.
Controller
Basic register number
Register numbers
JC-120MC
103000
103000 ... 103019
In this chapter, only the last two figures of a register number are specified, e.g.
MR 14. To calculate the complete register number, add the basic register
number of the corresponding device to the respective device, e.g. 103000.
Register
Description
MR 0
Error state
MR 1
Protocol
MR 2
Baud rate
MR 3
Number of data bits per character
MR 4
Number of stop bits
MR 5
Parity
MR 6
Interface standard
MR 10
Transmit buffer
MR 11
Transmit buffer filling level
MR 12
Receive buffer (without deleting characters on reading)
MR 13
Receive buffer (with deleting characters on reading)
MR 14
Receive buffer filling level
MR 15
Receive buffer, 16-bit, little endian
MR 16
Receive buffer, 16-bit, big endian
MR 17
Receive buffer, 32-bit, little endian
MR 18
Receive buffer, 32-bit, big endian
MR 19
Error counter
Introduction
Register numbers
Determining register
numbers
Registers - Overview
Содержание JC-120MC
Страница 1: ...User Manual JC 120MC Controller 60880901 We automate your success...
Страница 18: ......
Страница 40: ...40 Jetter AG 3 Identifying Hardware revisions see page 38 Related topics...
Страница 160: ......
Страница 186: ......
Страница 196: ......
Страница 395: ...Jetter AG 395 JC 120MC Programming Result When initializing the JX2 system bus the adjusted baud rate values were used...
Страница 485: ...Jetter AG 485 JC 120MC Programming Topic Page Programming 486 Registers 498 Contents...
Страница 521: ...Jetter AG 521 JC 120MC Programming Use 29 bit identifier Default 11 bit identifier...
Страница 586: ......
Страница 604: ......
Страница 633: ......