JETStream EUROJET Скачать руководство пользователя страница 3

17

Therefore, you must definitely observe the following Safety Instructions:

The JETSTREAM has substantial power. Before massage, you must definitely reduce the
pressure.
Do not utilize full thrust against soft parts of the body.

Switch off pump before adjusting angle of nozzle.
For large-area massage, reduce the strength to half  thrust.
In order to attach and detach the massage fitting switch off the pump.

To massage a single part of the body, grip the massage hose firmly. When using the hose keep
a distance to those parts of the body that require massaging.
Do not approch the suction filter with long hair unless tied back.
Before putting the massage hose on or taking it off, switch off the pump.

For point massage, hold the nozzle of the massage hose firmly in your hand under water. Guide
the nozzle of the massage hose over the required places but at some distance from them.

Do not dive to the intake screen (if there is one) with long, unrestrained hair.

For requirements regarding the appropriate electrical installation, please see „Information for the Electrician“,
as per part 7. Parts of the equipment that contain electrically live parts must be inaccessible to persons using
the pool. Units and unit parts containing electrical components must be installed or fixed in such a way that they
cannot fall into the water. Units of enclosure class I must be permanently connected to permanently laid cables.

1.4 Proper Operation

All units are intended soleley for operation in covered swimming pools and in open-air swimming pools with a
water temperature up to 35°C. The units are suitable for installing and operating in installations and rooms in
areas 1 and 2 as per EN-60335-2-41. The pump is normally installed in the walkway behind the pool wall, but it
must be ensured that the environment is dry and that the motor is protected by a suitably sized floor drain to
prevent flooding. The control panel should be installed either in a dry walkway or in an adjacent room, if possible
higher than the water level. Any kind of use other than the intended use is improper. The manufacturer will not
accept liability for any damage or injury resulting from improper operation; the user alone must bear this risk.
Proper operation also includes compliance with the operating, maintenance and repair conditions specified by
the manufacturer. Maintenance work, repair work and suchlike may only be performed by authorised persons.
The units may only be used by persons who are familiar with them and who have been informed about the
dangers. The relevant regulations for the prevention of accidents and the other generally recognised rules
relating to safety and to occupational medicine must be complied with. If unauthorised modifications are made
on the units, the manufacturer will not accept liability for any resulting damage or injury.

1.5 Product Liability

The user’s attention is expressly drawn to the fact that the unit may only be operated in the proper manner. If it
is operated in an improper manner, the user must bear sole responsibility. In such cases, therefore, the
manufacturer cannot accept any liability.

1.6 Procedure in an Emergency

Leave the water immediately, switch off the electrical supply to the unit by operating the main power switch or
circuit-breaker, and secure the unit to prevent it from being switched on again without authorisation.

1.7 Explanation of the Danger Symbols

Warning!
In these Operating Instructions, we have used this symbol to mark all texts which relate to
your safety. Please pass all safety instructions on to other users too.

In these Operating Instructions, we have used this symbol to mark all texts containing
instructions that are necessary for functional reasons. Please be sure to obey these instructions
in order to avoid damage to the unit.

Содержание EUROJET

Страница 1: ...1 INSTALLATION AND OPERATING INSTRUCTIONS EuroJet Eurojet Swimjet Instructions www agbudget co uk Luxury Swimming Pool Equipment at Budget Prices...

Страница 2: ...NIT 23 4 4 STRENGTH OF THE JET 23 4 5 MASSAGE 23 24 4 6 SWIMMING AGAINST THE CURRENT 24 4 8 WINTERIZATION 24 4 8 AGAIN OPERATION 24 5 SERVICE 24 6 FITTING INSTRUCTION FOR HANDGRIPS 25 7 INFORMATION FO...

Страница 3: ...nt is dry and that the motor is protected by a suitably sized floor drain to prevent flooding The control panel should be installed either in a dry walkway or in an adjacent room if possible higher th...

Страница 4: ...by placing in protective conduit or through adjacent cable ventilation ducts Tile plan fig 2 Render and tile to inner edge of wall niche Pools with plastic liner fig 3 Proceed as shown in fig 3 shutt...

Страница 5: ...mping frame air inlet tube for air suction end part to be installed 5 10 cm above water level pool wall sunk screw M 8 x 35 use clamping frame for cutting and drilling label top gasket concrete max wa...

Страница 6: ...fitted to the pool wall beforehand with concrete wall fixings The pump should be secured with anti vibration mountings Alternatively the pump should be secured with appropriate fixings on a concrete...

Страница 7: ...nce with EN 60335 2 41 Connection to the power supply is effected by means of a 5 x 2 5 mm 3N PE 400V cable or a 4 x 2 5 mm 3 PE 230 V cable Both a power switch with which the unit can be isolated fro...

Страница 8: ...irements must be met and safety precautions must be observed Before operating the unit for the first time rotate the pump by hand several times at the ventillating fan in the direction shown Do not se...

Страница 9: ...d detach the massage fitting switch off the pump For point massage hold the nozzle of the massage hose firmly in your hand under water Guide the nozzle of the massage hose over the required places but...

Страница 10: ...the surface is made to flow strongly without excessive effervescence being visible on the water surface 4 7 Winterization If the unit is installed in a pool where there is a danger of frost the water...

Страница 11: ...rete shuttered pools Fitting in steel aluminium or polyester pools 800 58 105 45 ca 736 JETSTREAM 45 58 7 36 8 50 nozzle hand grips are identical and can be interchanged broken screw are only needed f...

Страница 12: ...kers Pay attention to cable length and voltage drop For 230 V 16 A slow blow fuses or 16 A automatic circuit breakers Pay attention to cable length and voltage drop 4 Power consumption The maximum pow...

Страница 13: ...F2 S1 5 3 1 4 2 6 5 3 1 13 F3 1 2 F4 RD RD K2 A1 K2 2 1 3 A1 1 2 5 4x2 5mm K1 PE M1 3 M K1 3 5 4 2 14 6 2 60 min A2 A2 A1 N 1 18 S2 2 3 2 4 3 3 6 3 3 14 3 3 15 1 3 5 13 18 3 5 PE PE L1 L2 L3 N PE L1 L...