13
Disposal
When the appliance reaches the end of its life cycle, please remove the rechargeable battery from the handle prior to disposal by
puncturing and opening the plastic cover. Once opened, cut the wires attaching the battery to the handle and recycle or dispose of the
battery based on your local regulations. The rest of the unit can be discarded appropriately. N.B. Batteries must not be included with
normal household waste and should be taken to proper collection points to comply with Directives 2002/96/EC and 2006/66/EC.
Penalties may be applicable for incorrect disposal of this appliance.
5
.
Troubleshooting Guide
Problem
Cause
Corrective action
Jetpik is turned on but no water is
coming out of the nozzle.
1. There is no floss capsule is in nozzle or the
capsule is too old to function.
2. The water supply tube is clogged.
3. The nozzle was not fully engaged.
1. Insert a new capsule into the nozzle
and prime it.
2. Flush out the tube or replace it.
3. Release and re-‐install the nozzle.