2. Components and specifications
Bird cowl
A
B
MODEL
A
B
C
D
700 double sided
685
533
695
500
1050 double sided
1035
530
1045
590
Logpan
Firescreen - optional
For solid fuel applications only, a rotating bird cowl will assist in
preventing the effects of downdraft as it turns with the direction
of wind.
Other solid fuel cowls may be desired to achieve a visual design
and such cowls can be used but must not restrict airflow from the
flue pipe casings.
For gas applications an AGA approved cowl must be used.
C
D
•
Measurements are in mm and provided as a reference only.
•
Due to the nature of thick welded steel, it is normal and expected for some imperfections and slightly out of square components. It is recommended to not
begin construction of cavity or flue penetration points until after the unit is in place on site.
Optional 70mm surround
The surround should be installed before sliding the
unit into it’s final position.
Lift the surround above the fireplace outer flange and
locate the external tabs over the flange and lower
into place. Ensure the top folds clip on securely.
Tabs secure to outer flange