Users Instructions
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR
FUTURE REFERENCE.
General
WARNING - NEVER HANG CLOTHES OR OTHER ITEMS OVER THE APPLIANCE.
This appliance is designed for intermittent operation and is intended for the purposes of
room heating. It is designed to burn only the recommended fuels specified by Jetmaster
and shall not be used with any liquid fuels or as an incinerator.
In the United Kingdom the installation must be in accordance with:-
• The Building Regulations issued by the Department of the Environment or the Building
Standards (Scotland) (Consolidation) Regulations issued by the Scottish Development
Department.
• All relevant codes of practice and relevant parts of any local regulations, including those
referring to National and European standards.
• In other countries the installation must also conform to the national and local regulations in
force. This may include only the use of permitted fuels in some countries.
The fire is suitable for hearth installation only. The hearth should be non-combustible and to the
requirements and size as detailed in part J of the Building Regulations. A typical thickness of a
superimposed hearth is 48mm
Due to the newness of materials, the fire may give off a slight smell for a period after initial
lighting. This is quite normal and any odours will disperse after being used a few times.
Safety Information
Chimney Sweeping
Chimneys should be swept at least twice a year during the burning season. More frequent
sweeping may be necessary where fires are burned throughout the year or where low grade
wood or bituminous coal are used as fuels. Fires are provided with demountable throat restrictors
to facilitate chimney sweeping.
Chimney Fires
How Do I Know When I Have A Chimney Fire?
Excessive amounts of smoke.
Embers falling down the chimney
A roaring noise
Brickwork around the chimney can be very hot.
What Should I Do If I Have A Chimney Fire?
Raise the alarm in the house to let others know.
Call the Fire Service.
Reduce the burning rate of the fire by closing down the throat restrictor in a controlled way so
not to let fumes discharge into the room.