35
Service Manual
JL22
14
Frequently asked questions
Problems
Possible causes
Solutions
Coffee outlet
flow is too
slow
Ground coffee is too fine
Adjust the grinder
Dosage is much more over than expected
Calibrate after change of beans
Filter is blocked
Purification of the brewers
Leakage from fittings after cleaning the ES Brewers
Check and re-connect
Leakage from brewers O-ring or V-ring
Replace rings
Heavy
pollution on
drip tray
Sugar (on door) tunnel is not replaced
Mount back
Nozzle outlet is not right mounted after cleaning
Check and replace
Too fast ES
coffee flow
Ground coffee is too course
Adjust the grinder
Dosage is much less than expected
Calibrate or check the recipe settings
Heavy
pollution on
mixer
Mixer fan speed has not the right settings
Update the settings
The mixer is not cleaned for a long time
Take out the mixer and clean
Instant outlet is not in the right position.
Change and adjust the outlet.
Product is
disabled on
interface
Bean container outlet slide is closed after cleaning
Check and open it
Canister ran out of beans (detectable by the system)
Refill beans
Corresponding components are offline.
Check the background error tips, and contact
with Jetinno after-Sales
Instant
beverage
tasteless
Wrong ingredients refilled
Check and update
IPD settings are not reasonable
Update IPD settings
Container outlet is not in the right position
Adjust the outlet angle
Dosage is too less according to the settings
Recalibrate the container
Coffee
beverage
tasteless
ES Brewers heating is unplugged after cleaning
Plug in the heating bracket
Coffee powder fineness
Change ground coffee or adjust grinder
Beans or ground coffee quality
Change beans or ground coffee
Leakage from brewer O-ring or V-ring
Replace the sealing rings
Less ES
coffee volume
Leakage from the brewers.
Check and reconnect the brewer
Leakage from the brewer tubes
Re-connect it
Dosage is much more than expected
Re-calibrate
Boiler refill
fail
The machine is not used for a long time
Reboot the machine.
First use of the machine, there is air in the water system
Disconnect the power and try air exhaustive
again.
The machine
can't show
two-dimensio
nal code.
Bad Internet signal
Be sure if the machine is online, enhance the
signal
4G card
out of service
Contact after-Sales service of Jetinno