24
Machine (BTC) Machine (ES)
4.4.13
Canister and
motor parameters
Canister motor parameters page
Need to calibrate the grinder when first using
,
after
changing powders
,
canister or motor
,。
method of
calibration refer to the machine operation manual
Speed
:
dosage
:
Speed for calibration
:
Sample dosage
:
Motor test
:
Calibration
:
Filling powder in canister
(
there are raw material name
under the canister icon
)
C1
——Milk
C2
——chocolate
Grinder
——Coffee Beans
Canister calibration method:
1) Add powder to the corresponding canister,
shall not be less than 1/3 of canister
2) Place an empty cup under the outlet of the
canister
3) Click Sample dosage
:
Take the cup when
the powder is finished
4) Put an empty cup on the electronic scale
and discharge to zero
,
then put it under the
outlet of the canister
5) Click Calibration
:
select
“start” on the
dialog box
,
when the powder box stops, the
cup is taken out and weighed on the