Climb sens.

 

 

Set up of the sensor ascend sensitivity. If passing this threshold of ascend speed one segment of the 

indicator in the sensor introduction display becomes filled up, and at the same time an acoustic signal reports that 
the first stage  of ascend speed has been achieved.  For example: As long as  this  value  will be set up to  0.5m all 
segments of the indicator will become filled up, at the same time an acoustic signal will report achievement of the 
last stage of 2m/s ascend velocity. 

Descent sens. -  

Set up of the sensor descend sensitivity. If passing this threshold of descend speed one segment 

of the indicator in the sensor introduction display becomes filled up, and at the same time an acoustic signal reports 
that the first stage of descend speed has been achieved. For example: As long as this value will be set up to -2,0m 
all segments of the indicator will become filled up,  at the same time an acoustic signal  will report achievement of 
the last stage of -8m/s descend velocity. 

Beep period

 

– adjustment of the time between a group of tones of the Vario acoustic signals. The number of tones 

corresponds with the change of climb rate/descent rate which has occured during the set time. 

Trigger  level

 

–  adjustment  of  the  value  of  the  input  pulse  length,  after  whose  exceeding  the  extremes  become 

deleted  and  the  acoustic  signalling  of  the  climb  rate/descent  rate  starts.  As  long  as  the  MVario  input  is  not 
connected to the receiver channel the acoustic signalling  is switched on constantly and deleting of extremes does 
not proceed automatically. (We recommend connection of the input to the receiver channel which is controlled from 
the transmitter by a switch or by the throttle channel.) 

Reverse

 

– reversation adjustment of the input signal evaluation. (For instance, as long as the trigger level „Trigger 

level“ is set to 1.50 ms and „Reverse“ to OFF). MVario evaluates an infringement if the input signal is longer than 
1.50  ms  and  an  automatic  deletion  of  extremes  occurs.  Furthermore,  extremes  recording  starts  and  acoustic 
signalling of the Vario will be switched on. If the input signal lies below the trigger level, no recording of extremes 
will occur and signalling is switched off.)   

Alti.  above  sea 

–  adjustment  of  the  reference  altitude  above  sea  level  for  sensor  calibration.  For  exact 

measurements of the absolute altidude the known altitude above sea level must be set at a point, where the sensor 
will be operating further on.  

Beep Vario Alarm

 

– adjustment of the Morse alphabet character which will represent infringement of the Vario alert 

setting by an acoustical tone of the DUPLEX Tx transmitter module. 

Beep  Alti.  Alarm

 

–  adjustment  of  the  Morse  alphabet  character  which  will  represent  infringement  of  the  altidude 

alert setting by an acoustical tone of the DUPLEX Tx transmitter module 

Vario beep

 

– adjustment of one of 4 modes of the Vario acoustic signalling. 

„ON“

 is the  active signalling  of climb 

and descent flight. 

„ON – DESCENT“

 is the active acoustic signalling for descent flight only. 

„ON – CLIMB“

 is the 

active acoustic signalling for climb flight only. In the 

„OFF“

 mode the Vario acoustic signalling is switched off. These 

adjustments  do  not  affect  the  acoustical  alert  signalling  which  is  always  switched  on.  (If  you  want to be  informed 
about  violation  of  one  set  alert  only,  signalling  of  the  vario  must  be  switched  off.  We  do  not  recommend 
simultaneous setting of alerts as well as signalling of the Vario.) 

MVARIO MENU: 

ALARMS 

– 

by pushing the button D (downward arrow) you will change to the setup of particular 

alerts. If an adjusted parameter becomes passed over, the LCD screen of the JETIBOX will show in the second line 
of  the  introduction  screen  alternately  the  original  data  with  the  matching  alert  and  the  buzzer  of  the  transmitter 
module will emit the alert signal. The first tone is the revelation tone and the second one beeps the Morse code of 
the chacter representing the corresponding alert. If the alert is in position OFF, the given alert is switched off.  

Vario High Al.

 

– adjustment of the signal representing high climb rate, if the value measured by the Vario exceeds 

the set value, the alert will be activated.  

Vario low Al.

 - adjustment of the signal representing high descent rate, if the value measured by the Vario exceeds 

the set value, the alert will be activated.  

Alti. High Al.

 - adjustment of the signal representing the relative altitude, if the value of the relative altitude exceeds 

the set value, the alert will be activated  

MVARIO  MENU

SERVICE

 

–  by  pressing  button  D  (arrow  down)  you  will  change  to  depiction  of  the  firmware 

version and to renewal of the sensor default setting. 

Factory Defaults

 

– by simultaneous pressing of arrows R and L (right and left) the factory settings of the  MVARIO 

are loaded.  

MVARIO v. xx.xx ID xxxxx:xxxxx

 

– product marking with firmware version and series number (ID). 

Connecting the MVario  

The MVario comprises an 

exit 

marked Ext. (

black connector

) and an 

input

 (

red connector

). Via the 

exit 

(

black 

connector

)  of  the  sensor  informations  are  transmitted  to the  receiver  or  to the  JETIBOX,  and  it  serves  as  current 