Sensor MULi6s EX 

-1- 

 

 
The  MULi6s  sensor  is  used  for  monitoring  the  voltage  of  lithium  based  batteries  and  can  measure  the 
voltage  of  individual  battery  cells  using  the  7-pin  balance  connection.  With  the  help  of  this  sensor  it  is 
possible  to  monitor  the  minimum  and  maximum  cell  voltage  as  well  as  the  total  battery  voltage.  Not  only 
that,  but  the  Duplex  system  allows  for  alert  conditions  to  be  defined,  in  order  to  sound  an  audible  alarm 
when voltages drop below desired levels. 
 
The unit uses the 2.4GHz band to communicate,  not only allowing data to be sent from the transmitter to 
the receiver, but also allowing the receiver in the model to transmit data back to the user. In this manner, 
telemetric data obtained during operation is transferred in real-time and the current state of the system can 
be presented on the LCD screen of the Jeti Box. 
 

Dimensions 

36 x 20 x 5 mm 

Weight (with cables) 

6 g 

Accuracy 

– 4.4V 

Operating Temperature 

-

10°C 

 

+85°C 

Input voltage 

3.5 

– 8.4 V 

Current draw 

9 mA 

 

 
Parameter settings for MULi6s 

All  parameter  settings  and  data  readouts  must  be  performed  through  the  Jeti  Box  (available  separately). 
After connecting, the sensor identification, the number of cells connected to the unit, the lowest cell voltage 
and  the  number  (#)  of  the  cell  with  the  lowest  voltage  are  shown  on  the  LCD  screen  of  the  Jeti  Box.  By 
pressing the Down button of the Jeti Box, the MULi6s sensor menu is displayed. 
 

MULi6s MENU: 

Actual Value 

– 

Pressing the down button selects between displaying the following actual 

measured values: 

Individual voltage 

– By repeatedly pressing the D button, the voltage of each connected cell is shown 

 

MULi6s  MENU

MIN  /  MAX 

–  Navigating  the  menu  of  the  Jeti  Box  allows  the  minimum  and  maximum 

extremes  of  voltage  be  viewed.  These  values  are  automatically  erased  from  the  sensor  when  the 
configured  trigger  level  is  next  exceeded.  Alternatively  the  values  can  be  erased  manually  using  the  the 

Setting 

 Erase Data

 option. 

U MIN/MAX 

– Shows the minimum and maximum voltage of the currently selected cell. Using Up and Down 

keys moves between the cells, showing the Min/Max voltage and the cell number (#) for the corresponding 
cell. 

 
MULi6s MENU: 

Setting 

– Using the ‘down’ button of the Jeti Box, the following options can be accessed 

within this menu: 

Erase data 

– By simultaneously pressing the left and right arrow buttons, all measured parameters will be 

erased. 

Start  Trigger 

–  Set  the  voltage  at  which  monitoring  will  begin  and  any  existing  data  will  automatically  be 

erased. Use the Left and Right buttons to set the per-cell voltage. 

Beep Alarm 

– Set the letter of the Morse code to be represented by the alarm from the transmitter, when a 

low-voltage condition is encountered. 
Beep Error - Set up of a morse code letter representing a battery error. If after an identification sequence 
the  number  of  battery  cells  changes,  a  battery  error  will  be  generated  and  this  error  will  be  announced 
acoustically  by  emitting  the  above  mentioned  morse  code  letter.  This  function  may  be  deactivated  by 
pushing and holding of the button L (left).   
 

MULi6s  MENU: 

ALARMS 

–  Using  the  down  button,  it  is  possible  here  to  change  settings  for  individual 

alarms. 

Low Volt. Alarm 

– Set the threshold at which an alarm will be generated and your Tx module will emit the 

sound specified by the ‘Beep Alarm’ letter specified in ‘Settings’. This value can be Off, or between 0 and 
4.4V per cell. 