JETI model MT125 Скачать руководство пользователя страница 1

 MT125 & MT300 Sensor EX

   

- 1- 

 

 

 

Designation  of  MT  Sensors  are  temperature  measurements  of  devices  like  motors,  controllers, 

batteries  and  other  model  accessories.  Presentation  of  the  measured  data  is  realized  by  the  JETIBOX 
terminal and the wireless information transfer is ensued with aid of the DUPLEX 2,4GHz system.   
 

The Duplex System takes advantage  of the 2,4GHz-Band for communication which allows not only 

the transfer of remote control data to the model, but also in the opposite direction to the transmitter. The 
telemetric data measured during operation are transmitted in real time and the actual state of the data can 
be depicted on the JETIBOX LCD-display. The MT unit records minimum and maximum temperatures of 
the individual sensors and delivers besides that their actual values.  
The JETIBOX terminal takes care of parameter adjustments as well as of indications of measured data. 
The MT device consists of two parts. In the first instance of the MT module itself, which is recording the 
data  measured  by  temperature  sensors  connected  to  the  MT  module,  which  on  the  other  hand  can  be 
connected to the JETIBOX, to a receiver or to an Expander of the DUPLEX system. Keep an eye on the 
temperatures of the module and sensors in order not to expose them to temperatures higher than allowable 
– see technical data table.   
 

The MT module allows triggering of acoustic alerts by the individual sensors. These alerts can report 

of  temparature  limit  violations  by  too  high  or  too  low  temperatures  exceeding  adjusted  limits.  The 
acoustic  signal  is  generated  by  the  transmitter  module  DUPLEX  Tx  which  contains  a  small  siren.  The 
signals are differentiated by Morse codes in order to be able to distinguish between the individual types of 
alerts  referring  to  individual  sensors.  The  acoustic  signalling  of  parameter  violations  will  be  generated 
even  if  there  is  no  JETIBOX  available.  With  a  connected  JETIBOX  there  will  be  an  indication  on  its 
display showing which parameter has been violated. If several parameters have been violated at the same 
time the alert sounds change consecutively as well as the indications in the JETIBOX LCD-display.   

 

 
Technical Data

  

MT125 

MT300 

Dimensions  

19 x 14 x 4 mm 

19 x 14 x 4 mm 

Weight (without cables) 

10 g (4 g) 

6 g ( 3 g) 

Number of Temprature Sensors 

Temperature Sensor Range 

- 55°C +125°C 

- 40°C +300°C 

Measuring Accuracy 

0,5 °C 

5 °C 

MT-Module Operation Temperature 

- 10°C to + 85° C 

- 10°C to + 85° C 

Supply Voltage  

3,5 – 8,4V 

3,5 – 8,4V 

MT-Module & Sensor intrinsic consumption 

7 mA 

20 mA 

 

Connection of MT-Sensors 

 

In  the  MT125  Module  you  will  find  two  inputs  for  the  connection  of  temperature  sensors  coded  A 

and B. Connect the sensors to these inputs while paying attention to polarity (red sensor wire to + and the 
black  one  to  -  ).  Constituent  parts  of  the  MT300  sensor  are  two  sensors  which  comprise  a  loop  of  heat 
resistant conductor in the central part. A silicon tube sliding over the loop serves for fastening purposes. 
 

Fastening of the sensors 

Place  the  MT-Module  as  far  away  as  possible  from 
heat  sources  in  order  not  to  exceed  the  allowed 
maximum temperature.  
Sensors  of  the  MT125  Module  are  able  to  measure 
temperatures  up  to  125°C.  Fasten  the  sensor  to  the 
measured  object  as  secure  and  tight  as  possible  in 
order  to  prevent  contact  losses  and  herewith  falsify 
measurement  results.  Choose  a  fastening  method 
which  corresponds  to  the  assumed  maximum 
temperature  of  the  measured  object.  For  low 
temperatures  you  may  choose  glue  or  shrink  tubing 
(batteries,  controllers  etc.).  In  case  of  higher 
temperatures  fasten  the  sensors  by  means  of  the 
enclosed plastic tape. 

Отзывы: