JETI model Main Switch 200 ex Скачать руководство пользователя страница 5

User Manual: Electronic switch Main Switch 

 

-5- 

4.

 

Telemetry 

The Main Switch can measure the voltage, current, consumed capacity of the battery connected in the model 
and  also  the  Main  Switch  temperature.  Alarms  can  be  set  to  monitor  maximum  current,  minimum  voltage, 
maximum consumed capacity, and maximum temperature. 

Use  the  JETIBOX  or  the  DC/DS  transmitters  from  JETI  model  (in  the  JETIBOX  emulator)  for  parameter 
adjustment and data readout. After the JETIBOX is connected to the Main Switch, the sensor identification is 
shown and in the second line also the preadjusted actual measured data. By a long push of button R (right) a 
fast  deletion  of  all  measured  data  can  be  triggered  (min.  and  max.  voltage,  max.  current,  average  current, 
runtime, capacity). Fast deletion is indicated in the first line of the display by an asterisk „*“. 

MENU: ACT. VALUES –  

Volt. / Current –

 displays actual measured voltage and current passing through the switch. By simultaneously 

pushing arrows R and L (right and left) the zero value of the sensor current is calibrated. The actual measured 
current value is added to the zero current display, i.e. the so called zero shift.    

Capacity

 – shows the actual consumed capacity. 

Run  Time

  –  shows  the  total  time  of  current  passage  through  the  switch.  Included  is  also  the  time  when  the 

current has exceeded the adjusted current value 

Start Trigger 

in the 

SETTING 

menu.  

MENU

MIN / MAX

 – Display of extreme voltages and currents that occurred during the measurement. The 

extreme  recordings  are  deleted  automatically  or  can  be  deleted  in  the  menu  „

SETTING  –  Erase  Data“.

 

Automatic deletion occurs when the switch has just been connected to the voltage supply and the current, as 
set  in  the  menu 

Setting-Start  Trigger, 

is  exceeded.  If  after  connection  of  the  switch  the  set  current  is  not 

exceeded, values of the previous switch operation will be displayed.  

U MIN / MAX

 – Shows the minimum and maximum value of the measured voltage. 

I AVG / MAX

 – shows the average value of the measured current and its maximum. 

MENU: 

SETTING

 – basic setting of the switch  

Start  Trigger

  –  setup  of  a  current  value,  at  which  after  switch  connection,  the  recording  of  values  like 

minimum,  maximum  and  current  transit  time  starts.  If  the  adjusted  value  is  0A,  values  will  be  recorded 
immediately  after  the  connection  of  the  switch  to  its  power  supply  and  reading  the  data  of  the  previous 
operation will not be possible.  

Erase Data

 – by pushing arrows R and L (right and left) simultaneously the records of measured parameters 

will be deleted. 

First Parameter

 – adjustment of the display of the first parameter in the JETIBOX LCD, which is shown in 

the second line of the basic switch menu (the first line shows the identification, for instance MS 200)  

Second Parameter

 – adjustment of the display of the second parameter in the JETIBOX LCD, which is shown 

in the second line of the basic sensor menu (the first line shows the identification, for instance MS 200) 

Auto. Erase

 – This function of automatic data deletion after overstepping the trigger level can be activated or 

deactivated. 

 

Содержание Main Switch 200 ex

Страница 1: ...USER MANUAL ELECTRONIC SWITCH Main Switch By JETI model s r o 5 3 2014...

Страница 2: ...tions can be found on the manufacturer s website It is also possible to use the optional RC Switch instead of the magnetic switch The Main Switch is primarily designed for switching the main power sup...

Страница 3: ...must be connected to the Ext Duplex receiver input This also powers the measurement part of the Main Switch Fig 2 Block diagram of the Main Switch The ground of the Main Switch Ext is isolated Do not...

Страница 4: ...er grommets that prevent vibration transfer The input and output wire connections must be adequately dimensioned for the size of the transmitted current The connectors and the connecting wires used mu...

Страница 5: ...urrents that occurred during the measurement The extreme recordings are deleted automatically or can be deleted in the menu SETTING Erase Data Automatic deletion occurs when the switch has just been c...

Страница 6: ...rmware version and to renewal of the switch default setting Factory Defaults by simultaneous pressing of arrows R and L right and left the factory settings of the Main Switch are loaded M200 v xx xx I...

Страница 7: ...to the Main Switch Ext output using a three wire cable o After connecting the device the update will begin Fig 5 Update 6 Technical data Technical data Main Switch 100 Main Switch 200 Input voltage 8...

Страница 8: ...When claiming warranty repairs for the product always attach a proof of purchase Warranty and post warranty service is provided by your dealer or the manufacturer Technical support In case you are not...

Отзывы: