JETI model Central Box 200 Скачать руководство пользователя страница 7

EN

When  turning  on,  connect  the  batteries  first  and  then  turn  the 
system on via magnetic switch. Keep the same rule when switching 
off.  First  switch  the  system  off  via  magnetic  switch  and  then 
disconnect the batteries.

The Central Box is connected to the power supply, receiver, servos, 
controller/controllers  and  eventually  sensors.  Please  follow  the 
subsequent  general  guidelines  about  proper  connection  of  the 
Central Box and these other components.

3.1 Power  Supply

The Central Box can be powered from batteries which are directly 
connected, from voltage regulators connected to batteries or via 
BEC. When selecting power sources for the Central Box, be sure to 
follow  the  minimum  power  requirements. Together,  both  power 
supplies methods must be able to supply a 

15

A continuous and 

90A peak current. If the power source is not strong enough, the 
overload protection feature of the Central Box may not function 
correctly.
The power batteries are connected to the Central Box using MPX 
connectors.  The  Central  Box  allows  up  to  two  batteries  to  be 
connected.  During  use,  the  power  is  actually  supplied  from  the 
battery  with  the  higher  voltage.  If  the  voltage  is  the  same,  the 
power can be used from both batteries at the same time. When the 
voltage of the batteries is different, the power is not shared and 
each  pack  is  isolated  from  each  other.  This  allows  you  to  use 
batteries of different capacity, number of cells, and chemistry type. 
If the power for the Central Box is provided only from one battery, it 
can be connected via BATT1 or BATT2 input.

3     

Connection

7 EN

Содержание Central Box 200

Страница 1: ...figurationviaJETIBOX 14EN 4 1 Actualvalues 15EN 4 2 Minimum Maximumvalues 15EN 4 3 Setting 16 EN 4 4 OutPinSet 17EN 4 5 Alarms 18 EN 4 6 Serviceinformation 19EN 5 ConfigurationviatheDC DStransmitter 2...

Страница 2: ...at each servo output The Central Box can manage two batteries andfullysupportstheJETIEXtelemetrysystem Uptotworeceivers with serial PPM EX Bus output can be connected to the Central Box With JETI DC...

Страница 3: ...oad indication Easy settings changes via DC DS transmitter Firmware updates by user Suitable for use with high voltage HV servos Compact size for easy installation Each output is individually configur...

Страница 4: ...input for connecting receivers with serial output EXbusorPPM Switch input is reserved for connecting a magnetic switch or RC switch optionalaccessories BATT1 and BATT2 MPX connectors for connecting ba...

Страница 5: ...e output of telemetry data an input for telemetry sensors The Ext1 slot is also used for the firmware update connection using the USBa Rx1 primary input for connecting receivers with serial output EX...

Страница 6: ...theproperorientation the green LED glow steadily after 1 second indicating that the electronicswitchisturnedon Switching off is done in a similar manner when the magnet key is held to the target in th...

Страница 7: ...power requirements Together both power supplies methods must be able to supply a 15A continuous and 90A peak current If the power source is not strong enough the overload protection feature of the Cen...

Страница 8: ...Voltage 6V SERVO standard SERVO standard Rsat2 Rx2 Rsat2 Rx1 input voltage 4 14V Rsat2 Rx1 Rsat2 Rx2 7 Rx 1 Rx 2 Ext Out In BATT 8 8 channel servo interface 100 100 100 input voltage 4 14V Input Volta...

Страница 9: ...electedpowersupply Eg whenusing2Li xxcellswithouta regulator itisnecessarytouseservoslabeled HighVoltage Fig 6 Example of the Central Box 200 powered for use with HIGH Voltage servos RC Switch Magneti...

Страница 10: ...supply while the remaining servo outputsarestillpowered Rsat2 Rx1 Rsat2 Rx2 7 Rx 1 Rx 2 Ext Out In BATT 8 8 channel servo interface 100 100 100 input voltage 4 14V Input Voltage 8 4V SERVO High Voltag...

Страница 11: ...4 and 15 can be configured as servo outputs or as inputsfortelemetrysensors CentralBox200only Configuring the Central Box is in this way done by using a JETIBOX either directly connected to the Centra...

Страница 12: ...1 and Rx2inputs Ext1isaninputfortelemetrysensor Telemetryistransmittedtothe receiversviaEXBus Channels 14 and 15 can be configured as servo outputs or as inputsforconnectingtelemetrysensors CentralBox...

Страница 13: ...onnection EX Bus variant RC Switch Magnetic Switch Input Voltage SERVO Rsat2 Rx1 SERVO Rsat2 Rx2 SERVO Sensor Jetibox Sensor input voltage 4 14V Fig 11 Block diagram of Central Box 100 connection EX B...

Страница 14: ...e through the expander inputs The selected input is marked with a curly bracket brace after the input number eg 1 By pushing the R button right arrow it is possible to enter a selectedsensor whereyouc...

Страница 15: ...by the Central Boxontheinputsduringitsoperations Maximal voltage the highest voltage detected by the Central Boxontheinputsduringitsoperation Maximal current the highest current detected by the Centra...

Страница 16: ...By pushing the D button down arrow yougettothebasicsettingofthedevice FailSafe switcheson offoftheFailSafefunction IftheFail Safe function is deactivated there is no signal generated in any Central B...

Страница 17: ...n of the slot that will be used for the following settings In this menu the output deflection of the selected output is displayed as a percentage Y1 is the Central Box outputlabeled1 Y2istheCentralBox...

Страница 18: ...utput pulsesthatwillbegeneratedfromthereceiveratthesametime 4 5 Alarms CENTRAL BOX Alarms pushing the D button down arrow moves you to the menu for setting the alarms If the alarm is set to OFF theala...

Страница 19: ...of the firmware version and the menu for restoringthedefaultsettingsoftheCentralBox PresetToSetup pushing arrows R and L right and left together leadstoloadingthedefaultsettingsoftheCentralBox CBOXxx...

Страница 20: ...3 12 and newer with settingOutputmode EXBus ThereceivermustbeconnectedtotheCentralBoxviaEXbus Transmitter firmware version 2 02 and newer the device profile CBOX100 bin or CBOX200 bin recorded in the...

Страница 21: ...in15 setting of alternative output t3 Pin14 Ext2 P functions JETIBOX output for connecting JETIBOX eventually EX telemetry TelemetryInput inputforconnectingtelemetrysensor Servooutput servooutput ForC...

Страница 22: ...ail Safe output is performed During this time the last servo input is held After the selected time has elapsed the Central Box outputs behave accordingtosettingforeachspecificoutput Mode fail safemode...

Страница 23: ...atwillbegeneratedfromthereceiverinthesametime Fig 17 Device Explorer Servo Output Mapping 5 4Telemetry Temp actualtemperatureoftheCentralBox ShortedoutputsNo actualnumberofoverloadedoutputs Voltage ac...

Страница 24: ...mum maximum values in the Central Box Clear Now allows you to immediately clear the recorded battery capacity and minimum maximum values in the Central Box For description of individual items see the...

Страница 25: ...o yourPC 1 Connect the Central Box output labeled Ext1 with the USB adapterbymeansofinterconnectioncable 2 Start the firmware update program for the Central Box on your PC 3 For Central Box 100 Connec...

Страница 26: ...put into operation via magnet it is necessary to follow safety precautions for handling magnets The magnetismountedinahardaluminumcarrier 1 Keep the magnetickey a safe distancefrom all devicesthat cou...

Страница 27: ...te with magnetic switch 120uA Consumption on the off state with the RC switch 140 uA Operating temperature 20 C up to 75 C Weight 30 g Dimensions 63x38x17mm Dimensions of magnetic switch 30x21x5 mm Te...

Страница 28: ...repairs for the product always attach a proof of purchase Warranty and post warranty service is providedbyyourdealerorthemanufacturer Technicalsupport In case you are not sure about the setup or some...

Страница 29: ...100 200 Country of origin Czech republic The object of declaration described above is in conformity with the requirements of the folowing EU legislations and harmonized standards SN EN 61000 6 1 2007...

Страница 30: ...EN 30 EN...

Отзывы: