PAGE 24 of 54
The GSU screen will display:
Throttle channel “
Idle
” position
5.
Advance the throttle trim lever to maximum. Press
Select Menu
or the LED I/O board button switch
again
to store the R/C system’s pulse width for the turbine idle position. The red
Pump running
LED will turn off and the yellow
Standby
LED will illuminate.
The GSU screen will display:
Throttle channel “
Full Power
” position
6.
Advance the throttle stick to maximum. Press
Select Menu
or the LED I/O board button switch
again
to store the R/C system’s pulse width for the turbine full power position. The yellow
Standby
LED will turn off. If your ECU is set up for single channel operation skip to instruction number
11
.
The GSU screen will display:
AUX channel minimum “
Off
” position.
7.
If the ECU is set for two channel operation, continue to program the auxiliary channel. The green
OK
LED will illuminate again and initiates the learn mode for the three-position auxiliary channel.
8.
Move the auxiliary channel to the minimum position for
Off
and press
Select Menu
or the LED I/O
board button switch again
to store the R/C system’s pulse width for immediate shutdown of the
turbine. The green
OK
LED will turn off and the red
Pump running
LED will illuminate.
The GSU screen will display:
AUX channel center “
Start/Standby
” position
9.
Set the auxiliary channel to the middle position
for
Start/Standby
and press
Select Menu
or the
LED I/O board button switch again
to store the R/C system’s pulse width for the turbine to start and
run. The red
Pump running
LED will turn off and
the yellow
Standby
LED will illuminate.
The GSU screen will display:
AUX channel maximum “
Auto-Off
” position
10. Set the auxiliary channel to the maximum position for
Auto-Off
and press
Select Menu
or the LED
I/O board button switch again
to store the R/C system’s pulse width for a normal auto shut-off of the
engine. The yellow
Standby
LED will turn off.
Содержание P100-RX
Страница 15: ...PAGE 15 of 54 Complete System Connection Diagram RXi ...
Страница 16: ...PAGE 16 of 54 System Connection RXi Photo To fueltank To receiver ...
Страница 29: ...PAGE 29 of 54 Flashing E EGT sensor defective Last Off Condition Low RPM shut off from previous run ...
Страница 38: ...PAGE 38 of 54 Connection Diagram of the Smoke System ...