45/ 53
If calibration by weight measurement has been selected then the specific weight of the fuel must be
entered afterwards, otherwise the following query is skipped:
With the
keys, the value can be set, to confirm press the
key.
Table with specific weights of different fuels/media:
Specific weight
(kg/liter)
Medium
0.80
Jet-A1
0.75
Petrol
0.79
Methanol fuel
0.855
Smoke oil/paraffin oil
0.84
Diesel
0.88
Biodiesel
Step 1:
The first step is the interactive filling of the lines:
With the
Fill
Empty
keys, the pump is now interactively forward or reverse operated.
Fill the lines with this and add a certain initial amount e.g. approx. 500ml into the target vessel. At the
end of the process, all lines must be free of air and about 500ml liquid in the target vessel.
When finished, press the
key. The system now asks for the first quantity or weight value:
Read off the measured value on the measuring cup or the balance and enter it as the start value.
With the
keys, the value can be set, to confirm/continue press the
key.
Tip: To quickly adjust the value in addition to the
keys press and hold the
key!
Step 2:
The system is now ready to start the pump in forward mode.