Troubleshooting JPS2 ProShop II
Symptom
Possible Cause
Correction
Motor will not start
Low voltage.
Check power line for proper voltage.
Open circuit in motor or loose
connection.
Inspect all lead connections on motor for
loose or open connections.
Motor will not start: fuses
or circuit breakers blow.
Short circuit in line cord or plug.
Inspect cord or plug for damaged insulation
and shorted wires.
Short circuit in motor or loose
connections.
Inspect all connections on motor for loose or
shorted terminals or worn insulation.
Incorrect fuses or circuit breakers in
power line.
Install correct fuses or circuit breakers.
Motor overheats.
Motor overloaded.
Reduce load on motor.
Air circulation through the motor
restricted.
Clean motor fan with compressed air to
restore normal air circulation.
Motor stalls, resulting in
blown fuses or tripped
circuit.
Motor overloaded.
Reduce load on motor.
Short circuit in motor or loose
connections.
Inspect connections on motor for loose or
shorted terminals or worn insulation.
Low voltage.
Correct the low voltage conditions.
Incorrect fuses or circuit breakers in
power line.
Install correct fuses or circuit breakers.
Machine slows when
operating.
Applying too much pressure to
workpiece.
Feed workpiece more slowly.
Belt loose.
Tighten belt.
Loud, repetitive noise
coming from machine.
Pulley setscrews or keys are missing
or loose.
Inspect keys and setscrews. Replace or
tighten if necessary.
Motor fan is hitting the cover.
Tighten fan or shim cover.
Drive belt is defective.
Replace belt.
Blade not square with
miter slot, or fence not
square to blade.
Blade is warped.
Replace saw blade.
Table top not parallel to blade.
Adjust table parallel to blade.
Fence not parallel to blade.
Adjust fence parallel to blade.
Blade does not reach 90
degrees.
90 degree stop is out of adjustment.
Adjust 90 degree stop.
Table 4
Содержание ProShop II
Страница 28: ...28 14 1 1 Motor and Trunnion Exploded View...
Страница 32: ...32 14 2 1 Table and Cabinet Exploded View...
Страница 36: ...36 14 5 1 Blade Guard Assembly Exploded View...
Страница 39: ...39 15 0 Electrical Connections for JPS 10TSL...
Страница 40: ...40 427 New Sanford Road LaVergne Tennessee 37086 Phone 800 274 6848 www jettools com...