Jet MT Series Скачать руководство пользователя страница 9

 

7.0

  Electrical connections 

 

Electrical connections must be 

made  by  a  qualified  electrician  in  compliance 
with  all  relevant  codes.  This  machine  must  be 
properly  grounded  to  help  prevent  electrical 
shock and possible fatal injury.

 

7.1

  GROUNDING INSTRUCTIONS 

In  the  event  of  a  malfunction  or  breakdown, 
grounding  provides  a  path  of  least  resistance  for 
electric current to reduce the risk of electric shock.  

The trolley power cord must be correctly wired into 
the  hoist,  and  the  hoist  power  cord  must  be  fitted 
with  an  appropriate  UL/CSA  listed  plug,  or  can  be 
“hard-wired”  directly  to  a  control  panel.  If  hard-
wired,  make  sure  a  disconnect  is  available  for  the 
operator. 

If  a  plug  is  installed,  it  must  have  an  equipment-
grounding  conductor  and  a  grounding  prong.  The 
plug must be plugged into a matching outlet that is 
properly installed and grounded in accordance with 
all  local  codes  and  ordinances.  Do  not  modify  the 
plug. 

Improper  connection  of  the  equipment-grounding 
conductor can result in a risk of electric shock. The 
conductor  with  insulation  having  an  outer  surface 
that  is  green  with  or  without  yellow  stripes  is  the 
equipment-grounding  connector.  If  repair  or 
replacement  of  the  electric  cord  or  plug  is 
necessary,  do  not  connect  the  equipment-
grounding conductor to a live terminal. 

Check  with  a  qualified  electrician  or  service 
personnel  if  the  grounding  instructions  are  not 
completely understood, or if in doubt as to whether 
the tool is properly grounded. 

Repair  or  replace  damaged  or  worn  cord 
immediately. 

7.2

  Extension Cords 

If  an  extension  cord  is  necessary,  make  sure  the 
cord  rating  is  suitable  for  the  amperage  listed  on 
the  trolley’s  motor  plate.  An  undersize  cord  will 
cause  a  drop  in  line  voltage  resulting  in  loss  of 
power and overheating. 

The chart in Table 3 shows the correct size cord to 
use  based  on  cord  length  and  motor  plate  amp 
rating. If in doubt, use the next heavier gauge. The 
smaller the gauge number, the heavier the cord. 

 

 

 

 

 

Recommended Gauges (AWG) of Extension Cords 

Amps 

Extension Cord Length *  

25 

feet 

50 

feet 

75 

feet 

100 
feet 

150 
feet 

200 
feet 

< 5 

16 

16 

16 

14 

12 

12 

5 to 8 

16 

16 

14 

12 

10 

NR 

8 to 12 

14 

14 

12 

10 

NR 

NR 

12 to 15 

12 

12 

10 

10 

NR 

NR 

15 to 20 

10 

10 

10 

NR 

NR 

NR 

21 to 30 

10 

NR 

NR 

NR 

NR 

NR 

 
*based on limiting the line voltage drop to 5V at 150% of the 
rated amperes. 

NR: Not Recommended.

 

Table 3 

7.3

  Inspecting trolley motion 

1.  Before  closing  the  circuit  breaker  and  testing 

the  trolley,  check  that  wiring  has  been 
complete.  If  the  trolley  cannot  be  observed 
when  the  circuit  breaker  is  closed,  station  an 
observer within sight of the trolley to report any 
movement when power is applied to the trolley. 
Be  prepared  to  disconnect  power  if  trolley 
motor  starts  when  the  power  is  applied.  The 
trolley  must  remain  motionless  when  power  is 
applied. Find and correct any problems before 
continuing. 

2.  After  all  assembly  and  wiring  is  complete, 

operate  trolley  forward  and  back  a  short 
distance, then do  likewise for the entire  length 
of  the  beam.  Confirm  that  all  adjustments  and 
operations are satisfactory. 

Содержание MT Series

Страница 1: ...LaVergne Tennessee 37086 Document No M 140183 Ph 800 274 6848 Edition 1 06 2020 www jettools com Copyright 2020 JET Operating Instructions and Parts Manual MT Series 2 speed Electric Trolley This pdf...

Страница 2: ...move it Do not use to lift people or loads over people Warn others in the vicinity when lifting or transporting a load Avoid swinging load and hook Do not use in wet damp or poorly lit locations This...

Страница 3: ...rolley Frame Parts List 14 11 2 1 MT050 and MT100 Trolley Motor Exploded View 15 11 2 2 MT050 and MT100 Trolley Motor Parts List 16 11 3 1 MT050 and MT100 Trolley Electricals Exploded View 17 11 3 2 M...

Страница 4: ...nsion bolts and center load plate Wheels are hot forged steel and hardened steel comprises the gears and pinion which is driven by a planetary gear reducer Extensions are available to accommodate the...

Страница 5: ...e 3 phase Voltage 230V Current Draw amperage High Spd 0 8 1 2 2 2 3 8 3 8 Low Spd 0 6 0 9 1 7 2 2 2 2 Dimensions Figure 5 1 A 15in 382mm 15in 382mm 15 4in 392mm 17 4in 442mm 17 4in 442mm B 4 9in 124 5...

Страница 6: ...6 185mm 7 5 16 185mm C 12 13 16 325mm 12 13 16 325mm 14 3 16 360mm 15 3 4 400mm 15 3 4 400mm D 7 1 16 180mm 7 1 16 180mm 7 5 16 185mm 7 11 16 195mm 7 11 16 195mm E 2 15 16 4 15 16 2 15 16 4 15 16 3 15...

Страница 7: ...e measurement Spacers must be moved in sets of two to maintain centerline of trolley Distance between trackwheel flanges should be 1 8 to 2 inches 3 to 5mm greater than the beam flange width for strai...

Страница 8: ...nd orange wires in the hoist See Figure 6 6 The grey wire will control the forward movement of the trolley The orange wire will control the reverse movement of the trolley 5 Bring the trolley control...

Страница 9: ...doubt as to whether the tool is properly grounded Repair or replace damaged or worn cord immediately 7 2 Extension Cords If an extension cord is necessary make sure the cord rating is suitable for the...

Страница 10: ...and disc can be adjusted by the bolt shown in Figure 8 1 Loosen nut and fully tighten adjustment bolt Then loosen the bolt two rotations Retighten nut against motor housing to secure setting Figure 8...

Страница 11: ...by a qualified service technician Trolley performs slugglishly Rail beam is dirty or worn Clean rail as part of regular inspection process Trolley continues movement after brake applied Grease or oil...

Страница 12: ...umber and Serial Number of your machine available when you call will allow us to serve you quickly and accurately Non proprietary parts such as fasteners can be found at local hardware stores or may b...

Страница 13: ...13 11 1 1 MT050 and MT100 Trolley Frame Exploded View...

Страница 14: ...Bracket 1 MT100 A10 Load Bracket 1 11 MT050 A11 Spacer Washer 40 24 1 8 32 MT100 A11 Spacer Washer 46 27 1 8 32 12 MT050 A12 Spring Washer 7 8 4 MT100 A12 Spring Washer 1 4 13 MT050 A13 Hex Nut 7 8 9U...

Страница 15: ...15 11 2 1 MT050 and MT100 Trolley Motor Exploded View 23 17 18 11 10 20 19 22 21 1 5 2 3 4 6 13 12 24 8 9 7 19 16 15 14 11...

Страница 16: ...10 3 10 MT050 B10 Hex Head Bolt M6 1 60L 4 11 TS 2361061 Spring Washer M6 8 12 MT050 B12 Motor Stator Assembly 3 230V60Hz0 12 0 03kW 1 MT100 B12 Motor Stator Assembly 3 230V60Hz0 18 0 04kW 1 13 MT050...

Страница 17: ...ng Washer M6 6 3 MT050 C03 Electric Housing Cover 1 4 MT050 C04 Gasket 15 1 5 MT050 C05 Rubber Band 1 6 MT050 C06 Magnetic Contactor 110V LC1 D09 F7 2 7 MT050 C07 Contactor Rail 2PC 1 8 MT050 C08 Magn...

Страница 18: ...18 11 4 1 MT200 Trolley Frame Exploded View...

Страница 19: ...9 MT200 A09 Position Tube 48 34 69L 4 10 MT200 A10 Load Bracket 1 11 MT200 A11 Spacer Washer 54 34 1 8 32 12 MT200 A12 Spring Washer 1 1 4 4 13 MT200 A13 Hex Nut 1 1 4 7UNC 4 14 MT050 A14 Bumper 2 15...

Страница 20: ...20 11 5 1 MT200 Trolley Motor Exploded View...

Страница 21: ...09 Retaining Ring S 10 3 10 MT050 B10 Hex Head Bolt M6 1 60L 4 11 TS 2361061 Spring Washer M6 8 12 MT200 B12 Motor Stator Ass y 3 230V60Hz0 37 0 09kW 1 13 MT050 B13 Rectifier 1 14 TS 1482041 Hex Head...

Страница 22: ...6 6 3 MT050 C03 Electric Housing Cover 1 4 MT050 C04 Gasket 15 1 5 MT050 C05 Rubber Band 1 6 MT050 C06 Magnetic Contactor 110V LC1 D09 F7 2 7 MT050 C07 Contactor Rail 2PC 1 8 MT050 C08 Magnetic Contac...

Страница 23: ...23 11 7 1 MT300 and MT500 Trolley Frame Exploded View...

Страница 24: ...MT300 A10 Position Tube 50 40 83 5L 4 MT500 A10 60 47 83L 4 11 MT300 A11 Load Bracket 1 MT500 A11 1 12 MT300 A12 Stay Bolt 1 1 2 6UNC 390L 2 MT500 A12 1 3 4 x5UNCx415L 2 13 MT050 A13 Bumper 4 14 MT300...

Страница 25: ...25 11 8 1 MT300 and MT500 Trolley Motor Exploded View...

Страница 26: ...or 64 80 228 1 11 BB 6204ZZ Bearing 6204ZZ 1 12 MT300 B12 Oil Seal 35 20 8t 1 13 MT300 B13 Flange 1 14 MT300 B14 Spring Pin 5 16L 2 15 MT300 B15 Gearbox Gasket 1 16 F006050 C Retaining Ring Ext S 25 1...

Страница 27: ...Washer M6 6 3 MT050 C03 Electric Housing Cover 1 4 MT050 C04 Gasket 15 1 5 MT050 C05 Rubber Band 1 6 MT050 C06 Magnetic Contactor 110V LC1 D09 F7 2 7 MT050 C07 Contactor Rail 2PC 1 8 MT050 C08 Magneti...

Страница 28: ...nnections 12 1 MT Trolley wiring SF20000495 28101 KM6 R1 R3 1 3 M TRAVERSING E MOTOR 2 8P BRAKE BC FR3 M1 M4 M6 M5 M3 2 KM7 R2 R4 4 C KM5 2 4 2 6 3 1 5 2 6 4 1 3 5 KM5 KM6 3 4 KM7 FR3 2 4 3 E 1 E 2 4...

Страница 29: ...tional action needed JET has Authorized Service Centers located throughout the United States For the name of an Authorized Service Center in your area call 1 800 274 6846 or use the Service Center Loc...

Страница 30: ...30...

Страница 31: ...31...

Страница 32: ...32 427 New Sanford Road LaVergne Tennessee 37086 Phone 800 274 6848 www jettools com...

Отзывы: