All protective and safety devices must
be re-attached immediately after
completed cleaning, repair and
maintenance work.
Defective safety devices must be
replaced immediately.
Cleaning:
Regularly clean the machine housing
with a soft cloth preferably after each
use.
Keep the ventilation slots free from
dust and dirt.
If the dirt does not come off use a soft
cloth moistened with soapy water.
Never use solvents such as petrol,
alcohol, ammoniac water, etc. These
solvents may damage the plastic
parts.
Motor brushes:
The collector brushes are due to wear
and may need replacement.
- Disconnect the machine
from
the
power source, pull mains plug.
-remove the brush covers (A, Fig 11).
Fig 11
-Replace the collector brushes (B)
(Jet Article Number: JSMS10L-109
2 pieces needed).
-reattach the brush covers.
Saw blades:
Only use sharp saw blades.
Use carbide-tipped sawblades with a
negative chip angle only.
Never attempt to use ripping or
combination blades with this saw.
When cutting thin walled stock, it is
essential that you use a fine tooth
blade of at least 80 teeth.
The servicing of saw blades should
only be performed by a trained
person.
Replace a defective sawblade
immediately.
9. Trouble shooting
Motor doesn’t start
*No electricity-
check mains and fuse.
*Defective switch, motor or cord-
consult an electrician.
*Motor brushes worn-
Replace brushes.
Laser doesn’t work
*Defective line laser or power supply-
consult an electrician
Machine
vibrates
excessively
*
Stand on uneven surface-
adjust base for even support.
*sawblade damaged-
replace sawblade immediately
Cut is not square
*Bevel stop setting is bad.
*Workpiece fence setting is bad
Cutting surfaces is bad
*Wrong sawblade used
*resin collection on sawblade
*sawblade is dull
*workpiece inhomogeneous
*Feed pressure too high-
Do not force the workpiece.