6
Troubleshooting
Trouble Probable
Cause
Remedy
Drill does not operate
at normal speed.
Air pressure is too low.
Adjust air pressure to 90psi.
Air lines are twisted, or there is a
blockage in them.
Untwist or clean out air lines.
Air compressor is malfunctioning, or is
not sufficient capacity for the tool.
Replace air compressor.
Air regulator is malfunctioning.
Have regulator repaired or replaced at
an authorized service center.
Stops operating.
No air pressure.
Check air compressor and hoses.
Make sure compressor is set at 90psi,
and air lines are not twisted.
Trigger or throttle valve is
malfunctioning.
Have throttle valve/trigger inspected
and repaired at an authorized service
center.
Torque is diminished.
Air leakage.
Check connections at the air inlet, o-
rings, etc. Make adjustments/repairs
as needed.
Starts immediately as
soon as air is
connected without
trigger being pressed.
Throttle valve or trigger are
malfunctioning.
Inspect and repair throttle valve
and/or trigger.
Abnormal vibration
and/or excessive
heat develops in the
tool.
Improper lubrication.
Lubricate properly according to
instructions in this manual.