9
4. Slide handwheels (A) onto shafts at front and
both ends of table. If needed, tap with rubber
mallet to seat handwheels onto shafts. Tighten
set screws.
5. Thread handle (D) onto each handwheel and
tighten nut.
6. Loosen lock handles/nuts (Q or R, Figure 7-2)
and raise head using crank (E) to remove
shipping block from table.
5.6
Lubrication
The Mill-Drill must be checked for proper lubrication
before operating. See
sect.9.3.
6.0
Electrical connections
Electrical connections must be
made by a qualified electrician in compliance
with all relevant codes. This machine must be
properly grounded to help prevent electrical
shock and possible fatal injury.
The Mill-Drill is rated at 115/230V power, and is pre-
wired for 115 volt. The machine is provided with a
plug designed for use on a circuit with a
grounded
outlet
that looks like the one pictured in
A
, Figure 6-
1.
Before connecting to power source, be sure switch
is in
off
position.
It is recommended that the Mill-Drill,
when operated
on 115V
, be connected to a dedicated 20 amp circuit
with circuit breaker or fuse. When operated
on 230V
power
, connect it to a dedicated 15 amp circuit with
circuit breaker or fuse. If connected to a circuit
protected by fuses, use time delay fuse marked “D”.
NOTE: Local codes take precedence over
recommendations.
6.1
GROUNDING INSTRUCTIONS
This machine must be grounded. In the event of a
malfunction or breakdown, grounding provides a
path of least resistance for electric current to reduce
the risk of electric shock. This tool is equipped with
an electric cord having an equipment-grounding
conductor and a grounding plug. The plug must be
plugged into a matching outlet that is properly
installed and grounded in accordance with all local
codes and ordinances.
Do not modify the plug provided - if it will not fit the
outlet, have the proper outlet installed by a qualified
electrician.
Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. The
conductor with insulation having an outer surface
that is green with or without yellow stripes is the
equipment-grounding conductor. If repair or
replacement of the electric cord or plug is
necessary, do not connect the equipment-grounding
conductor to a live terminal.
Check with a qualified
electrician or service pe
r
sonnel if the grounding
instructions are not completely understood, or if
in doubt as to whether the tool is properly
grounded. Failure to comply may cause serious
or fatal injury.
Use only 3-wire extension cords that have 3-prong
grounding plugs and 3-pole receptacles that accept
the tool's plug.
Repair or replace damaged or worn cord
immediately.
Grounded, cord-connected tools intended for use on
a supply circuit having a nominal rating
less than
150
volts:
This tool is intended for use on a circuit that has an
outlet that looks like the one illustrated in
A,
Figure
6-1. An adapter, shown in
B
and
C
, may be used to
connect this plug to a 2-pole receptacle as shown in
B
if a properly grounded outlet is not available. The
temporary adapter should be used only until a
properly grounded outlet can be installed by a
qualified electrician
.
The green-colored rigid ear,
lug, and the like, extending from the adapter must
be connected to a permanent ground such as a
properly grounded outlet box.
Note:
In Canada, the
use of a temporary adaptor is not permitted by the
Canadian Electrical Code, C22.1.
Grounded, cord-connected tools intended for use on
a supply circuit having a nominal rating between
150
- 250 volts
, inclusive:
This tool is intended for use on a circuit that has an
outlet that looks like the one illustrated in
D,
Figure
6-1. The tool is intended to be used with a grounding
plug that looks like the plug illustrated in
D
. Make
sure the tool is connected to an outlet having the
same configuration as the plug. No adapter is
available or should be used with this tool. If the tool
must be reconnected for use on a different type of
electric circuit, the reconnection should be made by
qualified service personnel; and after reconnection,
the tool should comply with all local codes and
ordinances.
Figure 6-1
Содержание JMD-40GH
Страница 17: ...17 12 1 1 JMD 40GH 40GHPF Table Base and Column Assembly Exploded View ...
Страница 20: ...20 12 2 1 JMD 40GH 45GH non powerfeed Gear Head Assembly Exploded View ...
Страница 24: ...24 12 3 1 JMD 40GH 45GH non powerfeed Gears Assembly Exploded View ...
Страница 26: ...26 12 4 1 JMD 40GHPF 45GHPF powerfeed Gear Head Assembly Exploded View ...
Страница 30: ...30 12 5 1 JMD 40GHPF 45GHPF powerfeed Gears Assembly Exploded View ...
Страница 32: ...32 12 6 1 JMD 45GH 45GHPF Table and Base Assembly Exploded View ...
Страница 35: ...35 12 7 1 JMD 45GH 45GHPF Square Column Assembly Exploded View ...
Страница 37: ...37 13 0 Electrical Connections JMD 40GH 45GH series 13 1 Wiring Diagram 115V ...
Страница 38: ...38 13 2 Wiring Diagram 230V ...
Страница 40: ...40 427 New Sanford Road LaVergne Tennessee 37086 Phone 800 274 6848 www jettools com ...