7
3.0
Specifications
Model number ............................................................................................................................................
JCDC-2
Stock number .............................................................................................................................................. 717520
Motor and electricals:
Motor type ........................................................................ .totally enclosed fan cooled, induction, capacitor start
Horsepower ................................................................................................................................... 2 HP (1.5kW)
Phase .......................................................................................................................................................... single
Voltage ................................................................................................................................................. 230V only
Cycle ............................................................................................................................................................ 50Hz
Listed FLA (full load amps) ........................................................................................................................... 10 A
Start capacitor .......................................................................................................................... 300MFD 125VAC
Run capacitor ..................................................................................................................................... 30µF 250V
On/off switch .............................................................. push-button, magnetic contactor with overload protection
Motor speed ........................................................................................................................................ 2800 RPM
Power cord ........................................................................................................................ H05VV-F, 3G 1.5mm²
Power plug ...................................................................................................... VDE CE Plug 16A/250V installed
Recommended circuit and fuse/breaker size
1
............................................................................................. 16 A
Sound emission (at 9.84 ft./3m)
2
................................................................................................................ 76 dB
Remote control system ............................................ radio frequency (FCC approved); range up to 50 ft. (15 m)
RC transmitter battery .................................................................................................................... 2 x AAA, 1.5V
Timer setting ................................................................................................................................ 2, 4, 6, 8 hours
Performance:
Inlet diameter ................................................................................................................................ 6 in. (152 mm)
Inlet adaptors, number of ................................................................................................................................... 2
Inlet adaptors, diameter of ............................................................................................................. 4in. (100 mm)
Filter efficiency ............................................................................................................. 99% of 2 micron particles
Air Flow Rate with filters installed ......................................................... ........................ 1271 CFM (2159 m³/hr)
Air Velocity ............................................................................................ ............................ 6456 FPM (32.8 m/s)
Static pressure loss (WC) ..................................................................... ......................... 4 in-H
2
O (102 mmH
2
O)
Maximum static pressure loss (WC) ..................................................... ...................... 7.5 in-H
2
O (191 mmH
2
O)
Impeller:
Impeller diameter .................................................................................................................. 14-1/2 in. (368 mm)
Impeller type .......................................................................................................................................... radial fin
Impeller material .......................................................................................................................................... steel
Canister filter:
Filter type ........................................................................................................ cartridge and spunbond polyester
Canister filter diameter ........................................................................................................ 14-9/16 in. (370 mm)
Canister filter length .............................................................................................................. 22-5/8 in. (575 mm)
Filter surface area ................................................................................................................ 27.99 sq. ft. (2.6 m
2
)
Filter efficiency ............................................................................................................. 99% of 2 micron particles
Cleaning system ............................................................................................................ manual scraper rotation
Collection drum:
Capacity .................................................................................................................................................... 30 gal.
Diameter ........................................................................................................................... 19-11/16 in. (500 mm)
Height ................................................................................................................................... 22-1/4 in. (565 mm)
Material ........................................................................................................................................................ steel
1
Subject to local/national electrical codes. Recommendation based upon dedicated circuit.
2
The specified values are emission levels and are not necessarily to be seen as safe operating levels. As workplace
conditions vary, this information is intended to allow the user to make a better estimation of the hazards and risks
involved only.