Setup and Assembly 

Any missing parts or damage should be reported 
immediately to your JET

®

 distributor. Do not use a 

damaged  tool.  Read  this  instruction  manual 
thoroughly for operation, maintenance and safety 
instructions. 

Box contents: 

Needle scaler 

1  

Needle tube with needles/driver/spring 

Operation and parts manual  

Product registration card 

Operation 

 

The  needle  scaler  must  be 

properly  lubricated  before  operation.  See 
“Lubrication” section. 

 

Figure 1 

1. 

Place needles with spring and needle holder 
into  needle  tube.  (See  exploded  view  for 
proper orientation.) 

2. 

Place  needle  tube  over  barrel.  Push  until 
retainer  lever  reaches  desired  notch,  then 
twist needle tube to secure retainer lever in 
notch.  

3. 

Remove protective cap from air inlet (Figure 
1). If an in-line oiler is not being used, add 4 
or 5 drops of air tool oil (not included) into the 
air inlet. 

4. 

Blow  out  air  line  to  remove  any  dirt  or 
moisture,  then  connect  air  supply  hose  to 
tool. Set air pressure to 90 psi. 

IMPORTANT:

  Connecting  a  quick-change 

coupling  directly  to  the  tool  is  not 
recommended,  as  vibration  may  cause  the 

connection to fail. Instead, add a leader hose 
and  install  any  quick-change  couplings 
farther down the line. 

Note:  For  best  results,  prepare  work  surface  by 
removing  any  oil,  grease,  or  dirt  before  using 
needle scaler. Clean only 6 to 8 inches of surface 
area at one time, and make 2 or 3 passes. 

5. 

Hold needle scaler firmly with both hands, at 
approximately  45  degree  angle  from  work 
surface. 

6. 

Place needles upon work surface and press 
throttle lever. Pressure against throttle lever 
determines  speed  of  tool.  Do  not  exert 
excessive  pressure  against  work  surface  – 
let the tool do the work.  

7. 

Release throttle lever to stop needle scaler. 

Maintenance 

Lubrication 

The needle scaler should be lubricated 

daily

 (or 

before  each  use)  with  air  tool  oil  through  the  air 
inlet. During continual operation, it should be re-
oiled every 1 to 2 hours. This can be done with an 
in-line  oiler,  or  manually.  If  done  manually, 
proceed as follows: 

1. 

Disconnect air hose from tool. 

2. 

Place 4 or 5 drops of air tool oil into air inlet. 

NOTE: Air tool oil not provided; it is available 
at most major hardware and tool stores. SAE 
#10 oil or sewing machine oil may be used 
as a substitute. Do not use detergent oil. 

3. 

Re-connect  air.  Run  needle  scaler  at  low 
throttle  without  load  for  a  few  seconds  to 
distribute the oil throughout tool. 

4. 

When  finished  operating  needle  scaler, 
disconnect air hose. Wipe off housing with a 
dry cloth. Place 4 or 5 drops of air tool oil into 
air inlet; re-connect air and run tool for a few 
seconds to distribute the oil. Disconnect air. 

Storage  

Avoid  storing  the  needle  scaler  in  very  humid 
locations  which  promotes  rusting  of  internal 
mechanisms.  Always  oil  the  tool  and  disconnect 
air hose before storage. 

Содержание JAT-800A

Страница 1: ...Pneumatic Needle Scaler 505802 JAT 800A Operation Parts Manual M 505802 Edition 1 08 2019 JET 427 New Sanford Road LaVergne TN 37086 Ph 800 274 6848 www jettools com Copyright 2019 JET...

Страница 2: ...placing the tip against the work surface 11 Do not operate air tool without its guards in place Do not modify the tool 12 Do not operate this tool while tired or under the influence of drugs alcohol o...

Страница 3: ...e do not hold workpiece by hand 36 Use both hands to operate needle scaler Keep hands away from needle area 37 Use only needles specifically designed for use with a needle scaler 38 Keep needles again...

Страница 4: ...ual may not encompass all possible workplace environments The operator is expected to take appropriate precautions and exercise common sense As with any tool operation safety of operator and bystander...

Страница 5: ...381 mm Housing material Steel Net weight 6 28 lb 2 85 kg Shipping weight 6 68 lb 3 03 kg 1 All testing and specification are performed at 90 psi 2 The specified values are emission levels and are not...

Страница 6: ...fore using needle scaler Clean only 6 to 8 inches of surface area at one time and make 2 or 3 passes 5 Hold needle scaler firmly with both hands at approximately 45 degree angle from work surface 6 Pl...

Страница 7: ...nued use in either capacity will cause damage to the tool Tool Pressure JET Air Tools operate on 70 to 100 psi pounds per square inch air pressure measured at the tool when the tool is operating Set t...

Страница 8: ...8 JAT 800A Pneumatic Needle Scaler Figure 2 Recommended arrangement of air piping and air line system...

Страница 9: ...Lubricate with air tool oil according to instructions in this manual Loss of power erratic action Low air pressure Verify compressor has proper CFM rating for tool Check compressor regulator setting s...

Страница 10: ...274 6848 Monday through Friday 8 00 a m to 5 00 p m CST Please have the stock number and serial number of your tool available when you call so that we may serve you quickly and accurately Some parts...

Страница 11: ...1 10 729597 1 Lock ring 1 28 730218 Alignment shim 2 29 729608 Rear valve block 1 30 1012591 Pin 2 31 729604 Valve 1 Index Part No Description Qty 32 729606 Front valve block 1 33 730219 Piston 1 35 7...

Страница 12: ...thorized Service Centers located throughout the United States For the name of an Authorized Service Center in your area call 1 800 274 6846 or use the Service Center Locator on the JET website More In...

Отзывы: