18
6. Tighten nut (C).
7. Repeat for other blade guide assembly.
Figure 25
Figure 26
9.13
Chip brush
The chip brush (B, Figure 19) must be properly
adjusted and maintained in working condition;
otherwise damage to blade can occur. Adjust
the brush so that its bristles overlap the blade.
Replace brush if it becomes worn or damaged.
9.14
Limit switch
The stop screw (F, Figure 27) activates a limit
switch to shut off the saw when it reaches down
position.
The stop screw has been set at the factory. If
future adjustment is needed, loosen the hex nut
and rotate the screw, then retighten the hex nut.
Figure 27
10.0
Operating controls
To start saw, push On button (A, Figure 28).
To stop saw before it reaches the end of cut,
push Off button (B). The saw will automatically
stop at the end of a cut.
The Emergency Stop (C) shuts down all
functions on the band saw. The machine will not
start if the emergency stop is still engaged. To
start the machine, turn the emergency stop
button until it disengages
The flow of coolant to the blade area is
controlled by the valves (D).
Figure 28
IMPORTANT:
When cutting magnesium, never
use soluble oils or emulsions (oil-water mix) as
water will greatly intensify any accidental
magnesium chip fire. See your industrial coolant
supplier for specific coolant recommendations