![Jet GHB-1236 Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/jet/ghb-1236/ghb-1236_operation-and-maintenance-instructions_645273011.webp)
11
7.
Compound Rest
– Lubricate three ball oilers
(F, Figure 6-4) once daily with Mobil DTE
Oil
Heavy Medium.
8.
Cross Slide
– Lubricate four ball oilers (G,
Figure 6-4) once daily with Mobil DTE
Oil
Heavy Medium.
9.
Longitudinal Feed Handwheel
– Lubricate
ball oiler (H, Figure 6-4) once daily with Mobil
DTE
Oil Heavy Medium.
Figure 6-4
10.
Tailstock
– Lubricate ball oilers (I, Figure 6-5)
once daily with Mobil DTE
Oil Heavy
Medium.
11.
Leadscrew/Feed Rod
– Lubricate ball oilers
once daily (J, Figure 6-5) with Mobil DTE
Oil
Heavy Medium.
Figure 6-5
7.0
Electrical connections
All electrical connections must
be done by a qualified electrician in compliance
with all local codes and ordinances. Failure to
comply may result in serious injury.
The GHB-1236 Lathe is rated at 230-volt power
only. It is not provided with a power plug; you may
either attach a proper 230V UL-listed plug, or
“hardwire” the machine directly to a service panel
(make sure a disconnect is available to the
operator).
Before connecting to power source, be sure switch
is in
off
position.
It is recommended that the lathe be connected to a
dedicated 15 amp circuit with circuit breaker or
fuse.
Local codes take precedence over
recommendations.
7.1
GROUNDING INSTRUCTIONS
This tool must be grounded. In the event of a
malfunction or breakdown, grounding provides a
path of least resistance for electric current to
reduce the risk of electric shock. This tool is
equipped with an electric cord having an
equipment-grounding conductor. If a plug is used,
the plug must be inserted into an appropriate outlet
that is properly installed and grounded in
accordance with all local codes and ordinances.
Improper connection of the
equipment-grounding conductor can result in a
risk of electric shock. Check with a qualified
electrician or service person if you are in doubt
as to whether the outlet is properly grounded.
Do not modify the plug – if it will not fit the
outlet, have a proper outlet installed by a
qualified electrician.
The conductor with insulation having an outer
surface that is green with or without yellow stripes
is the equipment-grounding conductor. If repair or
replacement of the electric cord or plug is
necessary, do not connect the equipment-
grounding conductor to a live terminal.
Use only 3-wire extension cords that have 3-prong
grounding plugs and 3-pole receptacles that accept
the tool's plug.
Repair or replace damaged or worn cord
immediately.
If used with a plug:
Grounded, cord-connected tools intended for use
on a supply circuit having a nominal rating between
150-250 V inclusive:
Содержание GHB-1236
Страница 18: ...18 12 0 Thread and feed chart Table 3 ...
Страница 20: ...20 13 2 1 Headstock Assembly Exploded View ...
Страница 21: ...21 ...
Страница 24: ...24 13 3 1 Gearbox Assembly Exploded View ...
Страница 25: ...25 ...
Страница 28: ...28 13 4 1 Apron Assembly Exploded View ...
Страница 31: ...31 13 5 1 Cross Slide Assembly Exploded View ...
Страница 33: ...33 13 6 1 Compound Rest Assembly Exploded View ...
Страница 36: ...36 13 7 1 Tailstock Assembly Exploded View ...
Страница 39: ...39 13 9 1 Feed Rod Assembly Exploded View ...
Страница 41: ...41 13 10 2 Motor and Change Gear Enclosure Exploded View ...
Страница 43: ...43 13 11 1 Stand Brake Coolant Pump Exploded View ...
Страница 44: ...44 ...
Страница 46: ...46 13 12 1 Electrical Box Assembly Exploded View ...
Страница 48: ...48 13 13 1 Steady Rest and Follow Rest Parts List ...
Страница 51: ...51 13 15 1 Accessories Exploded View ...
Страница 53: ...53 14 0 Wiring Diagram for GHB 1236 ...
Страница 55: ...55 This page intentionally left blank ...
Страница 56: ...56 427 New Sanford Road LaVergne Tennessee 37086 Phone 800 274 6848 www jettools com ...